background image

SuperiorFireplaces.US.com

900806-00NC

24

PARTS

This list contains replaceable parts used in your fi replace. When ordering parts, follow the instructions listed under Replacement Parts on 

Page 29 

of this manual.

KEY NO. CATALOG NO. DESCRIPTION

36" Models 42" Models

QTY

1

J6811

MICRO SWITCH

1

2

J4667

SCREW, #10 X 5/8 PH AB BLK

2

3

J4387

ELECTRICAL DUCT ASSEMBLY

1

4

J6976

DIVERTER, DRAFT  GL3000

1

J6977

DIVERTER, DRAFT  GL4000

1

5

J3946

RETAINER, AIR ROD

1

6

J3947

RETAINER, DAMPER ROD

1

7

F2880

EXTENSION DEFLECTOR

2

F2881

EXTENSION DEFLECTOR

2

8

J6918

SPACER, TOP  42GC17

4

9

J6905

CLIP, SPRING  G36GC16-1

2

10

J3952

SEPARATOR, AIR

1

J4060

SEPARATOR, AIR M42

1

11

J4955

BUSHING DBL INSUL

2

12

See Page 25

LEFT REFRACTORY

1

13

See Page 25

RIGHT REFRACTORY

1

14

See Page 25

REAR REFRACTORY

1

15

See Page 25

BOTTOM REAR REFRACTORY

1

16

See Page 25

BOTTOM FRONT REFRACTORY

1

17

J6802

STRAIN RELIEF

1

18

J6859

SWITCH, HIGH LIMIT 280 DEG F

1

J3942

SWITCH, HIGH LIMIT 300 DEG. F

1

19

J3975

ROD, SCREEN FORMED 36" C.C.

2

J4084

ROD, SCREEN FORMED 42" C.C.

2

20

J6903

STOP, DOOR  G36GC17-2

1

21

J3976

COLLAR, TRANSITION 6" B-VENT

1

22

J3980

ASSY, AIR KIT DOOR 36"

1

23

J6900

PLATE,OUTSDE AIR COVER 36E44-6

1

24

J3992

DEFLECTOR, SMOKE

1

J4081

DEFLECTOR, SMOKE

1

25

J6895

RETAINER, REFRACTORY  36E28

2

26

J4054

GRATE, ASSEMBLY

1

J4055

GRATE, ASSEMBLY

1

27

J4048

PAN, BURNER

1

J4049

PAN, BURNER

1

28

J4053

TUBE, BURNER

1

J4083

TUBE, BURNER

1

29

J4051

BRACKET, BURNER

1

30

J4094

SHIELD, PILOT

1

J4095

SHIELD, PILOT

31

J7320

CLIP, BURNER

1

32

J4769

NUT 10-24 HEX

1

33

J4605

SCREW 10-24X1/2 PPH MS BLK. OX

1

34

J7221

HOLDER, INJECTOR (NG)

1

J7222

HOLDER, INJECTOR

1

35

J7203

INJECTOR (NG) #31

1

J7207

INJECTOR (NG) #29

1

J7220

INJECTOR, LP #52

1

J7217

INJECTOR, LP #50

1

36

J4116

PILOT,NG#51 TP,CONV.36 199.761

1

J4120

PILOT,LP#30 TP,CONV.36 199.767

1

37

J4121

INJECTOR, NG #51

1

J4122

INJECTOR, LPG #30

1

38

J4489

SCREW #8 X 3/8 PPH B ZINC

2

39

H6244

VALVE ,NAT,DEBIE FIXE,SIT  (0.820.618)

1

H3142

VALVE,PROP,DEBIT FIXE, SIT (0.820.617)

1

40

J4044

BRACKET, VALVE

1

41

J8042

097159 0 PIEZO, WITH NUT

1

42

J4533

GAS LINE FLEX 18" W/SHUT OFF

1

43

J6893

COLLAR,CHMNY STARTER   36C19-1

1

44

J4098

HARNESS, WIRE, M36

1

45

J4099

HARNESS, WIRE, JUMPER

1

46

J4956

NUT PUSH-ON.765X.445X.011 BLCK

2

47

J5666

SCREEN 22X21

2

J4085

SCREEN, 26H X 24.5

2

PARTS AVAILABLE NOT SHOWN

J7274

VERMIC, PLN BAG , #1.00

1

J7275

PAN MATERIAL-0.4# PLN BAG EMBE

1

J7276

LAVA, BAG, #5 PLAIN

1

Содержание BRT4036TMN-B

Страница 1: ...b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L ins...

Страница 2: ...s valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or optional accessory items when n...

Страница 3: ...d to the hazards of high sur face temperature and should stay away to avoid burns or clothing ignition 22 Clothing or other flammable material should not be placed on or near the appliance 23 The draf...

Страница 4: ...0 CSA 2 22 standard as vented gas fireplace WARNING This gas appliance must not be con nected to a chimney flue serving a separate solid fuel burning appliance Models BRT4036TMN B 4336TMN B 4536TMN B...

Страница 5: ...manual shut off must be a T handle type valve WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need...

Страница 6: ...22 1 4 566 mm 24 610 mm w o Brick 29 1 4 743mm 31 788 mm w o Brick N 36 915 mm 40 1016 mm V 7 178 mm 7 178 mm G 32 5 8 829 mm 34 864 mm w o Brick 39 1 2 1004 mm 41 1 4 1048 mm w o Brick O 37 940 mm 4...

Страница 7: ...7 6 cm Max 6 15 2 cm Max A B Outer Surround Combustible Material May Be Used TOP VIEW SAFE ZONE Perpendicular Wall Figure 6 Side Clearances Top View Cross Section CLEARANCES Minimum clearances to comb...

Страница 8: ...he supply line to the appliance using a 1 2 NPT black iron gas line terminating 2 5 16 above the bottom of the appliance The gas line must be installed through the lower left side access point or alte...

Страница 9: ...to a chimney flue serving a separate solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adaptor or a chimney liner syst...

Страница 10: ...ecking for Spillage Check this area along entire top edge of fireplace opening Smoke or flame should be drawn into appliance opening CHECKING FOR PROPER VENTING After completing and checking electrica...

Страница 11: ...G TYPE CL2 UL 105 C 25 ft length MAXIMUM or equivalent Figure 14 Wall Switch Wiring Diagram WARNING Do not wire remote wall switch to main power supply Standard 120v household current WALL SWITCH INST...

Страница 12: ...lack iron gas line with teflon tape or pipe joint compound Check with local building codes WARNING Gaslinehookupshouldbedonebyyour gas supplier or a qualified service person WARNING Before you proceed...

Страница 13: ...re surface and leave about a 1 2 gap under lower grate members to allow air to flow see Figure 21 Figure 18 Connecting Flexible Gas Line to Millivolt Valve P I L O T ON OFF IN OUT Gas Shutoff Valve Fl...

Страница 14: ...log 5 into notch on left of log 2 see Figure 24 Rest lower end of log 5 on grate as shown in Figure 25 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 25 and position u...

Страница 15: ...inner right of log 1 see Figure 28 Rest lower end of log 5 on middle grate finger as shown in Figure 29 6 Place log 6 into notch on top right of log 1 see Figure 28 Rest lower end of log 6 on top of...

Страница 16: ...m it must be a continuous surface and not on blocks without a solid surface This will prevent the entry of cold air by means of conduction through the total bottom of appliance see Figure 31 CAUTION A...

Страница 17: ...closed Operating the appliance with the doors partially open can result in improper venting of flue products 6 Repeat the process for the opposite door assembly 7 To adjust doors slide them partially...

Страница 18: ...ectric power to appliance 4 Place damper in full open position 5 Fully open glass doors if installed 6 Remove front refractory brick access panel 7 Turn gas control knob clockwise to the OFF position...

Страница 19: ...ally by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and...

Страница 20: ...UIVALENT OR HIGHER RATING THERMOSTAT WIRE 18 GA RED WHITE EXTERNAL WIRING USE ONLY CLASS 2 N C SW VENT SAFETY SHUTOFF SWITCH WHITE TH TP TP TH WALL SWITCH NOT SUPPLIED MANUAL DAMPER SWITCH N O SW TO 1...

Страница 21: ...efective or too long 2 Thermopile not generating sufficient voltage 1 Check electrical connections 2 See Pilot will not stay lit above Frequent pilot outage 1 Pilot flame may be too low causing safety...

Страница 22: ...ee Gas Line Hook Up Page 12 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive blocka...

Страница 23: ...non approved parts can result in poor performance and safety hazards MODEL CAT NO INTERIOR F3198 BRT4536TMN B White Herringbone F3199 BRT4536TMP B White Herringbone F3202 BRT4542TMN B White Herringbon...

Страница 24: ...N 6 B VENT 1 22 J3980 ASSY AIR KIT DOOR 36 1 23 J6900 PLATE OUTSDE AIR COVER 36E44 6 1 24 J3992 DEFLECTOR SMOKE 1 J4081 DEFLECTOR SMOKE 1 25 J6895 RETAINER REFRACTORY 36E28 2 26 J4054 GRATE ASSEMBLY 1...

Страница 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Страница 26: ...CRIPTION QTY J4096 LOG SET 1 J4246 LOG 9 FIREPIT SPLIT 1 2 J7241 LOG REAR 22 1 3 J4242 LOG 11 75 TOP ROUND 1 4 J4243 LOG 16 TOP SPLIT 1 5 J4244 LOG 13 5 Y TOP SPLIT 1 6 J4245 LOG 11 TOP 1 KEY NO CATAL...

Страница 27: ...xed Glass Door Brushed Brass finish F1001 FD42P 42 Fixed Glass Door Platinum finish OPTIONAL OUTSIDE AIR KITS Optionalkithelpsoffsetthenegativepressureoftenexistingintoday stightlyconstructed homes Ne...

Страница 28: ...42 Perimeter Trim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1122 PCBM 36 36 Millivolt NG to LP...

Страница 29: ...sit our web site at Superiorfireplaces US com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 32: ...eplace uses Dealer name P900806 00 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Отзывы: