background image

31

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. B  10/2016

Innovative Hearth Products
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The product body, fi rebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 
against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 
Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 
replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 
pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND 
LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 
months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 
the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 
provided. The product body, fi rebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded 
from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 
and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 
(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-
tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 
venting confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 
after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a 
particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 
Limited Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание BRT4036TMN-B

Страница 1: ...b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L ins...

Страница 2: ...s valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or optional accessory items when n...

Страница 3: ...d to the hazards of high sur face temperature and should stay away to avoid burns or clothing ignition 22 Clothing or other flammable material should not be placed on or near the appliance 23 The draf...

Страница 4: ...0 CSA 2 22 standard as vented gas fireplace WARNING This gas appliance must not be con nected to a chimney flue serving a separate solid fuel burning appliance Models BRT4036TMN B 4336TMN B 4536TMN B...

Страница 5: ...manual shut off must be a T handle type valve WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need...

Страница 6: ...22 1 4 566 mm 24 610 mm w o Brick 29 1 4 743mm 31 788 mm w o Brick N 36 915 mm 40 1016 mm V 7 178 mm 7 178 mm G 32 5 8 829 mm 34 864 mm w o Brick 39 1 2 1004 mm 41 1 4 1048 mm w o Brick O 37 940 mm 4...

Страница 7: ...7 6 cm Max 6 15 2 cm Max A B Outer Surround Combustible Material May Be Used TOP VIEW SAFE ZONE Perpendicular Wall Figure 6 Side Clearances Top View Cross Section CLEARANCES Minimum clearances to comb...

Страница 8: ...he supply line to the appliance using a 1 2 NPT black iron gas line terminating 2 5 16 above the bottom of the appliance The gas line must be installed through the lower left side access point or alte...

Страница 9: ...to a chimney flue serving a separate solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adaptor or a chimney liner syst...

Страница 10: ...ecking for Spillage Check this area along entire top edge of fireplace opening Smoke or flame should be drawn into appliance opening CHECKING FOR PROPER VENTING After completing and checking electrica...

Страница 11: ...G TYPE CL2 UL 105 C 25 ft length MAXIMUM or equivalent Figure 14 Wall Switch Wiring Diagram WARNING Do not wire remote wall switch to main power supply Standard 120v household current WALL SWITCH INST...

Страница 12: ...lack iron gas line with teflon tape or pipe joint compound Check with local building codes WARNING Gaslinehookupshouldbedonebyyour gas supplier or a qualified service person WARNING Before you proceed...

Страница 13: ...re surface and leave about a 1 2 gap under lower grate members to allow air to flow see Figure 21 Figure 18 Connecting Flexible Gas Line to Millivolt Valve P I L O T ON OFF IN OUT Gas Shutoff Valve Fl...

Страница 14: ...log 5 into notch on left of log 2 see Figure 24 Rest lower end of log 5 on grate as shown in Figure 25 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 25 and position u...

Страница 15: ...inner right of log 1 see Figure 28 Rest lower end of log 5 on middle grate finger as shown in Figure 29 6 Place log 6 into notch on top right of log 1 see Figure 28 Rest lower end of log 6 on top of...

Страница 16: ...m it must be a continuous surface and not on blocks without a solid surface This will prevent the entry of cold air by means of conduction through the total bottom of appliance see Figure 31 CAUTION A...

Страница 17: ...closed Operating the appliance with the doors partially open can result in improper venting of flue products 6 Repeat the process for the opposite door assembly 7 To adjust doors slide them partially...

Страница 18: ...ectric power to appliance 4 Place damper in full open position 5 Fully open glass doors if installed 6 Remove front refractory brick access panel 7 Turn gas control knob clockwise to the OFF position...

Страница 19: ...ally by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and...

Страница 20: ...UIVALENT OR HIGHER RATING THERMOSTAT WIRE 18 GA RED WHITE EXTERNAL WIRING USE ONLY CLASS 2 N C SW VENT SAFETY SHUTOFF SWITCH WHITE TH TP TP TH WALL SWITCH NOT SUPPLIED MANUAL DAMPER SWITCH N O SW TO 1...

Страница 21: ...efective or too long 2 Thermopile not generating sufficient voltage 1 Check electrical connections 2 See Pilot will not stay lit above Frequent pilot outage 1 Pilot flame may be too low causing safety...

Страница 22: ...ee Gas Line Hook Up Page 12 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive blocka...

Страница 23: ...non approved parts can result in poor performance and safety hazards MODEL CAT NO INTERIOR F3198 BRT4536TMN B White Herringbone F3199 BRT4536TMP B White Herringbone F3202 BRT4542TMN B White Herringbon...

Страница 24: ...N 6 B VENT 1 22 J3980 ASSY AIR KIT DOOR 36 1 23 J6900 PLATE OUTSDE AIR COVER 36E44 6 1 24 J3992 DEFLECTOR SMOKE 1 J4081 DEFLECTOR SMOKE 1 25 J6895 RETAINER REFRACTORY 36E28 2 26 J4054 GRATE ASSEMBLY 1...

Страница 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Страница 26: ...CRIPTION QTY J4096 LOG SET 1 J4246 LOG 9 FIREPIT SPLIT 1 2 J7241 LOG REAR 22 1 3 J4242 LOG 11 75 TOP ROUND 1 4 J4243 LOG 16 TOP SPLIT 1 5 J4244 LOG 13 5 Y TOP SPLIT 1 6 J4245 LOG 11 TOP 1 KEY NO CATAL...

Страница 27: ...xed Glass Door Brushed Brass finish F1001 FD42P 42 Fixed Glass Door Platinum finish OPTIONAL OUTSIDE AIR KITS Optionalkithelpsoffsetthenegativepressureoftenexistingintoday stightlyconstructed homes Ne...

Страница 28: ...42 Perimeter Trim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1122 PCBM 36 36 Millivolt NG to LP...

Страница 29: ...sit our web site at Superiorfireplaces US com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 32: ...eplace uses Dealer name P900806 00 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Отзывы: