INSTALLATION  

Continued

Figure 30 - Air Kit Handle Location

Figure 31 - Sealing Between Appliance and Framing

Figure 32 - Installing Optional Glass Door

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

The outside air kit may be installed on the left side of fi replace only. 
The vent can be installed through any outside wall a minimum of three 
feet below fi replace termination cap. The handle to operate damper 
door for outside air inlet will be located inside the left “screen pocket” 
of fi rebox 

(see 

Figure 30

)

. Pull handle to open or push to close.

Air Kit 
Handle

Screen 
Pocket

Side 
Framing

Side 
Framing

Caulk Here

Pack Insulation

Spring Clip

Insert Pin Into Spring Clip

Insert Bottom Pivot Pin Into Pivot 
Plate and Swing Door Into Vertical 
Position

Pivot Plate

Slide Top Pin 
Into Door Track

APPLIANCE ENCLOSURE

Before fi nishing enclosure around appliance, inspect all joints around 
outer surround. Any gaps between nailing fl anges and framing should 
be sealed with noncombustible insulation or caulking.
If appliance is mounted on a raised platform, it must be a continuous 
surface and not on blocks without a solid surface. This will prevent 
the entry of cold air by means of conduction through the total bottom 
of appliance

 (see

 Figure 31

).

 CAUTION: Air inlet ducts are not to terminate in 

attic space.

 CAUTION: Use only glass doors certifi ed for use 

with this appliance.

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

NOTE:

 Glass door may be heavy for some individuals. Please request 

help if needed.
The BRT4036, BRT4336, BRT4536, BRT4042, BRT4342 and BRT4542 
B-vent fi replaces are approved for use with optional bi-fold glass doors 

(see Accessories, 

Page 27

).

 Glass panels may be ordered and installed 

anytime after fi replace installation is complete.
Follow these steps to install left and right panels:
1.  With handle at the bottom, completely fold panel on its hinges.
2.  With handle facing center of fi rebox opening, insert lower pivot pin on 

glass door panel into hole in pivot plate on bottom edge of fi replace 
opening 

(see 

Figure 32

)

.

3.  Keeping folded door tilted, slide upper two pins into guide track 

found under upper facial edge of fi rebox opening. 

4.  Tilt glass assembly fully vertical until outer pivot pin snaps into 

mounting hole in upper spring clip 

(see 

Figure 32

)

.

5.  Once top and bottom pins are secured, unfold door into the closed 

position.

Содержание BRT4036TMN-B

Страница 1: ...b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L ins...

Страница 2: ...s valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or optional accessory items when n...

Страница 3: ...d to the hazards of high sur face temperature and should stay away to avoid burns or clothing ignition 22 Clothing or other flammable material should not be placed on or near the appliance 23 The draf...

Страница 4: ...0 CSA 2 22 standard as vented gas fireplace WARNING This gas appliance must not be con nected to a chimney flue serving a separate solid fuel burning appliance Models BRT4036TMN B 4336TMN B 4536TMN B...

Страница 5: ...manual shut off must be a T handle type valve WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need...

Страница 6: ...22 1 4 566 mm 24 610 mm w o Brick 29 1 4 743mm 31 788 mm w o Brick N 36 915 mm 40 1016 mm V 7 178 mm 7 178 mm G 32 5 8 829 mm 34 864 mm w o Brick 39 1 2 1004 mm 41 1 4 1048 mm w o Brick O 37 940 mm 4...

Страница 7: ...7 6 cm Max 6 15 2 cm Max A B Outer Surround Combustible Material May Be Used TOP VIEW SAFE ZONE Perpendicular Wall Figure 6 Side Clearances Top View Cross Section CLEARANCES Minimum clearances to comb...

Страница 8: ...he supply line to the appliance using a 1 2 NPT black iron gas line terminating 2 5 16 above the bottom of the appliance The gas line must be installed through the lower left side access point or alte...

Страница 9: ...to a chimney flue serving a separate solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adaptor or a chimney liner syst...

Страница 10: ...ecking for Spillage Check this area along entire top edge of fireplace opening Smoke or flame should be drawn into appliance opening CHECKING FOR PROPER VENTING After completing and checking electrica...

Страница 11: ...G TYPE CL2 UL 105 C 25 ft length MAXIMUM or equivalent Figure 14 Wall Switch Wiring Diagram WARNING Do not wire remote wall switch to main power supply Standard 120v household current WALL SWITCH INST...

Страница 12: ...lack iron gas line with teflon tape or pipe joint compound Check with local building codes WARNING Gaslinehookupshouldbedonebyyour gas supplier or a qualified service person WARNING Before you proceed...

Страница 13: ...re surface and leave about a 1 2 gap under lower grate members to allow air to flow see Figure 21 Figure 18 Connecting Flexible Gas Line to Millivolt Valve P I L O T ON OFF IN OUT Gas Shutoff Valve Fl...

Страница 14: ...log 5 into notch on left of log 2 see Figure 24 Rest lower end of log 5 on grate as shown in Figure 25 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 25 and position u...

Страница 15: ...inner right of log 1 see Figure 28 Rest lower end of log 5 on middle grate finger as shown in Figure 29 6 Place log 6 into notch on top right of log 1 see Figure 28 Rest lower end of log 6 on top of...

Страница 16: ...m it must be a continuous surface and not on blocks without a solid surface This will prevent the entry of cold air by means of conduction through the total bottom of appliance see Figure 31 CAUTION A...

Страница 17: ...closed Operating the appliance with the doors partially open can result in improper venting of flue products 6 Repeat the process for the opposite door assembly 7 To adjust doors slide them partially...

Страница 18: ...ectric power to appliance 4 Place damper in full open position 5 Fully open glass doors if installed 6 Remove front refractory brick access panel 7 Turn gas control knob clockwise to the OFF position...

Страница 19: ...ally by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and...

Страница 20: ...UIVALENT OR HIGHER RATING THERMOSTAT WIRE 18 GA RED WHITE EXTERNAL WIRING USE ONLY CLASS 2 N C SW VENT SAFETY SHUTOFF SWITCH WHITE TH TP TP TH WALL SWITCH NOT SUPPLIED MANUAL DAMPER SWITCH N O SW TO 1...

Страница 21: ...efective or too long 2 Thermopile not generating sufficient voltage 1 Check electrical connections 2 See Pilot will not stay lit above Frequent pilot outage 1 Pilot flame may be too low causing safety...

Страница 22: ...ee Gas Line Hook Up Page 12 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive blocka...

Страница 23: ...non approved parts can result in poor performance and safety hazards MODEL CAT NO INTERIOR F3198 BRT4536TMN B White Herringbone F3199 BRT4536TMP B White Herringbone F3202 BRT4542TMN B White Herringbon...

Страница 24: ...N 6 B VENT 1 22 J3980 ASSY AIR KIT DOOR 36 1 23 J6900 PLATE OUTSDE AIR COVER 36E44 6 1 24 J3992 DEFLECTOR SMOKE 1 J4081 DEFLECTOR SMOKE 1 25 J6895 RETAINER REFRACTORY 36E28 2 26 J4054 GRATE ASSEMBLY 1...

Страница 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Страница 26: ...CRIPTION QTY J4096 LOG SET 1 J4246 LOG 9 FIREPIT SPLIT 1 2 J7241 LOG REAR 22 1 3 J4242 LOG 11 75 TOP ROUND 1 4 J4243 LOG 16 TOP SPLIT 1 5 J4244 LOG 13 5 Y TOP SPLIT 1 6 J4245 LOG 11 TOP 1 KEY NO CATAL...

Страница 27: ...xed Glass Door Brushed Brass finish F1001 FD42P 42 Fixed Glass Door Platinum finish OPTIONAL OUTSIDE AIR KITS Optionalkithelpsoffsetthenegativepressureoftenexistingintoday stightlyconstructed homes Ne...

Страница 28: ...42 Perimeter Trim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1122 PCBM 36 36 Millivolt NG to LP...

Страница 29: ...sit our web site at Superiorfireplaces US com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 32: ...eplace uses Dealer name P900806 00 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Отзывы: