Figure 15 - Manual Shutoff Valve Installation
Typical Exterior Wall Gas Shutoff
Installation
Key
Extension
Shutoff
Valve
Figure 16 - Routing Incoming Gas Line
A
B
1/2" NPT Incoming
Black Iron Gas Line
Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side
7"
7"
Alternate Gas Supply
BRT4036TMN-B/TMP-B,
BRT4336TMN-B/TMP-B,
BRT4536TMN-B/TMP-B
BRT4042TMN-B/TMP-B,
BRT4342TMN-B/TMP-B,
BRT4542TMN-B/TMP-B
A
8
5
/
8
" (21.9 cm)
10
1
/
2
" (26.7 cm)
Figure 17 - Sediment Trap
Incoming 1/2" Gas
Line Permitted by
Local Codes
Sediment
Trap (Not
Supplied)
3" Min.
(7.6 cm)
IHP recommends that a black iron gas line be routed from the gas
source, through a sediment trap
(see
Figure 17
)
and into appliance.
Once connected through appliance, a fl exible gas line may be used
for ease of installation to gas control valve
(see
Figure 18, Page 13
).
Before connecting black iron gas line to inside of appliance a sediment
trap must be included outside appliance between gas line and gas
shutoff valve. It must extend down 3" beyond center of pipe. Prepare
incoming black iron gas line with tefl on tape or pipe joint compound
(Check with local building codes).
WARNING: Gas line hookup should be done by your
gas supplier or a qualifi ed service person.
WARNING: Before you proceed, make sure your
gas supply is OFF.
CAUTION: Do not kink fl exible gas line.
GAS LINE HOOK-UP
A manual shutoff valve has been included in the appliance’s gas sup-
ply system. You may consider installing an extra gas shutoff valve
outside appliance’s enclosure (check with local codes) where it can
be accessed more conveniently with a key through a wall as shown
in
Figure 15
.
In conformance with local codes, route a 1/2" NPT gas line to appliance
through hole in left side of fi rebox or sub-fl oor as shown in
Figure 16
.
CAUTION: Compounds used on threaded joints of
gas piping shall be resistant to the action of Liquefi ed
Petroleum (LP or propane) and should be applied lightly
to ensure excess sealant does not enter the gas line.
WARNING: All gas piping and connections must be
tested for leaks after the installation is completed.
After ensuring that the gas valve is on, apply a com-
mercial leak detection solution to all connections and
joints. If bubbles appear, leaks can be detected and
corrected.
Do not use an open fl ame for leak testing and do not
operate any appliance if a leak is detected.