15
AVSI-10 Interview Room System Setup and User Guide
SECTION 3: SYSTEM SETUP
DC12-1000R power adapter
FEMALE-POW power cable
Alarm terminations
Ground (G) terminals
Wire
coupler
ALARM IN 1 terminal
CAB-SWITCH
cable to AVSI
switch
4.
Plug the other end of the
FEMALE-POW power cable
into a DC12-1000R power adapter.
Do not
plug the power adapter
into an electrical outlet at this time.
5.
At the alarm terminations, push and hold in the orange button associated with the
ALARM IN 1
terminal, insert the
CAB-SWITCH cable
green
wire all the way in, and then release the orange button. Tug on the wire to ensure that is securely
attached.
6.
At the alarm terminations, push and hold in the orange button associated with one if the
G
(ground) terminals, insert the
CAB-SWITCH cable
white
wire all the way in, and then release the orange button. Tug on the wire to ensure that is securely
attached.
Test the AVSI switch
7.
Power on the UPS.
8.
Plug the DC12-1000R power adapter shown in the photo in step 3 above into one of the outlets on the back of the UPS.
9.
Flip the AVSI switch to the up (record) position. Verify that the
green
light is
on
. If this step and the following step do
not produce the expected results, check the connections to the switch and power adapter. Contact your vendor support
organization if additional help is needed.
10. Flip the AVSI switch to the down (standby) position. Verify that the
red
light is
on
. Leave this switch in the down position.