OPERATION & MAINTENANCE MANUAL SWE155F
47
(32°F), mix coolant with anti-freezing liquid.
Select proper storage position
:
The machine must be
kept at well-ventilated indoor place, if the machine has
to be stored outdoors, select level, firm ground and
cover the machine with a sheet.
2.2.2 During Storage
Note
When it's necessary to perform the rust-preventive operation while the machine is at indoor,
open the doors and windows to ventilate and prevent gas poisoning.
During storage, operate the machine to travel, swing and dig for 2 to 3 cycles at least once a month so as
to lubricate machine, and charge the machine battery.
Before operating, check cooling water level and lubrication status.
Air condition must run once a month.
2.2.3 After Storage
Note
Start engine only in well-ventilated condition.
Remove lubricating grease on piston rod surface.
Apply grease to all lubricating parts.
Check engine oil level, keep it in specified level, if not,
and refill engine oil. If some water is found to mix in
the oil, replace it.
Check fuel level and bleed the air.
Check its level to ensure that it is with the standard
range.
Start and run the engine at half speed for several
minutes before operation with full load.
Cycle all hydraulic function for several times.
Содержание SWE155F
Страница 20: ...OPERATION MAINTENANCE MANUAL SWE155F 13 23 Center of Gravity Label 24 Hydraulic Oil Label 25 Grease Label ...
Страница 141: ...OPERATION MAINTENANCE MANUAL SWE155F 134 4 4 10 Hoses ...
Страница 176: ...OPERATION MAINTENANCE MANUAL SWE155F 169 5 TECHNICAL SPECIFICATION ...
Страница 180: ...OPERATION MAINTENANCE MANUAL SWE155F 173 5 1 4 Electrical Schematic ...
Страница 182: ...OPERATION MAINTENANCE MANUAL SWE155F 175 5 1 6 Hydraulic Schematic ...
Страница 184: ...OPERATION MAINTENANCE MANUAL SWE155F 177 6 NOTE FOR SAFETY ...