43
9
Troubleshooting
9.1
Troubleshooting of LED Indicator
9.1.1
Troubleshooting of LED Indicator
Phenomenon
Causes
Troubleshooting
LED indicators
and LCD cannot
be turned on
1. The polarity of DC cables is
opposite.
2. The DC input voltage is too
slow or there is no DC input
voltage.
1. Disconnect inverter from its dual power
supplies.
2. Check the polarity of DC input.
Reconnect DC cables if necessary.
3. Wait for DC voltage to return to the
operating voltage.
4. If the phenomenon still exists, contact
Sungrow service dept..
“RUN” indicator
and LCD turn on
and turn off after
a while
irregularly
DC voltage supplied is not
stable.
1. Wait for DC voltage to return to the
operating voltage.
2. If the phenomenon still exists, contact
Sungrow service dept..
“RUN” indicator
flashes regularly
There is not sufficient DC
power.
1. Wait for DC power to recover.
2. If the phenomenon still exists, contact
Sungrow service dept..
“RUN” indicator
goes out
Inverter may be in “standby”,
“startup” or “key-stop” state.
1. Wait a while for inverter entering into
“Run” state.
2. Perform “start” command in the LCD
screen.
3. If the phenomenon still exists, contact
Содержание SG2K5TL
Страница 2: ......
Страница 6: ......
Страница 10: ...IV...
Страница 16: ...SG2K5TL SG3KTL SG4KTL 31 User Manual 6...
Страница 52: ...SG2K5TL SG3KTL SG4KTL 31 User Manual 42 Press the ribbing Pull outwards Disconnect DC connectors...
Страница 60: ...SG2K5TL SG3KTL SG4KTL 31 User Manual 50 10 3 Overview of Complete LCD Menu Fig 10 1 Menu Tree...
Страница 76: ...66 Temperature Derating Curve 1 0 2 45 60 Pnom P U Ambient temperature C...
Страница 79: ......