SG2K5TL/SG3KTL/SG4KTL-31
User Manual
56
10.11
Load Default Settings
If “Load default” is performed, all running information and historical records
will unrecoverable cleared off. And all parameters not including protective
parameters and time will return to the default values.
1. Press ENTER to enter general control screen from the default screen.
2. Press
▼
to navigate arrow-pointer to “Set-param” and then press ENTER.
3. Press
►
to move cursor to the right and press button
▼
to set password 1111. And
press ENTER to enter into parameters settings.
4. Press
▼
to navigate arrow-pointer to “Sys-param” and then press ENTER.
5. Press
▼
to navigate arrow-pointer to “Load default” and then press ENTER.
6. Press
►
to move right and press
▼
to input the password 1111.
7 Inverter will begin to return to the factory value after pressing ENTER.
10.12
Firmware Version
1. Press ENTER to enter general control screen from the default screen.
2. Press
▼
to navigate arrow-pointer to “Set-param” and then press ENTER.
3. Press
►
to move cursor to the right and press button
▼
to set password 1111. And
press ENTER to enter into parameters settings.
4. Press
▼
to navigate arrow-pointer to “Sys-param” and then press ENTER.
5. Press
▼
to navigate arrow-pointer to “Firmware Version” and then press ENTER to
get the version information.
Содержание SG2K5TL
Страница 2: ......
Страница 6: ......
Страница 10: ...IV...
Страница 16: ...SG2K5TL SG3KTL SG4KTL 31 User Manual 6...
Страница 52: ...SG2K5TL SG3KTL SG4KTL 31 User Manual 42 Press the ribbing Pull outwards Disconnect DC connectors...
Страница 60: ...SG2K5TL SG3KTL SG4KTL 31 User Manual 50 10 3 Overview of Complete LCD Menu Fig 10 1 Menu Tree...
Страница 76: ...66 Temperature Derating Curve 1 0 2 45 60 Pnom P U Ambient temperature C...
Страница 79: ......