Operation of LCD Menu
10
55
10.10
Deviation of E-tot Adjustment
Where there is deviation between E-tot in the inverter LCD screen and energy
recorded in the energy metering device, you should perform energy-adj settings as
the following indications.
1. Press ENTER to enter general control screen from the default screen.
2. Press
▼
to navigate arrow-pointer to “Set-param” and then press ENTER.
3. Press
►
to move cursor to the right and press button
▼
to set password 1111.
4. Press ENTER to confirm command.
5. Press
▼
to navigate arrow-pointer to “Sys-param” and then press ENTER.
6. Press
▼
to navigate arrow-pointer to “Energy-adj” and then press ENTER.
7. Press
►
to move right and press
▼
to set off-set value. Press ENTER to confirm
the settings.
The positive symbol “+” can also be changed to negative symbol “-”. The adjustable
range is from -9999~+9999 kWh.
(Energy-adj value)= (Real measured value)-(E-tot reading value).