10 Operation of LCD Display Panel
User Manual
66
The contrast value ranges from 0 to 100. The recommended value is 50
or 60.
10.5
Detailed Running Information
On the main screen, there is some basic information about the inverter. For more
detailed running information, please operate as follows.
Main Screen
(
Press
ENTER
)
→
Menu
→
Run-info
(
Press
ENTER
)
LCD screen will show four detailed running information pages. Scroll pages by
pressing
h
/
j
.
“DC power input” represents the total input power of
PV1 and PV2.
“Vdc” indicates the DC voltage of each input.
“Idc” indicates the DC current of each input.
“Pdc” indicates the DC power of each input.
“Indep mode” is the PV configuration mode of the two
PV inputs.
indicates the corresponding input is at work.
“P-W” is inverter output active power.
“S-Va” is inverter output apparent power.
“Country” is inverter selected country code.
“Grid code” is inverter selected grid code.
“Vac” is phase voltage.
“Iac” is phase current.
“Pac” is AC output of each phase.
“F” is frequency of each phase.
“CO2-reduce” indicates total CO2 emission reduction
due to the inverter.
“E-month” is the energy generation in this month.
“h-Total” is the total running hours of the inverter.
“T-today” is today running time of the inverter.
“Temp” is the internal temperature of the inverter.