![Sungrow SG10KTL-EC Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/sungrow/sg10ktl-ec/sg10ktl-ec_user-manual_1396649059.webp)
User Manual
5 Electrical Connection
49
Item
Description
Item
Description
1
Master inverter
4
5-conductor connection at digital input
2
Slave inverter
5
Ripple control receiver
3 RS485
connection
6
Grid
Fig. 5-15
Connect the ripple control receiver for inverters with Ethernet connections
Item
Description
Item
Description
1
Master inverter
5
5-conductor connection at digital input
2
Slave inverter
6
Ripple control receiver
3 Ethernet
cable
7
Grid
4 Router
-
-
Connect the cables to DI terminal block according to the terminal assignment.
1.
Strip approximately 4.5 cm of protective layer off the DI cables.
2.
Lead the DI connection cables through water-proof terminal and the
communication terminal lid.
3.
Strip approximately 6 mm of insulation off the insulated wires.
4.
Release the sockets of the four-pole plug with a screwdriver and insert
individual insulated conductors into corresponding pins of the four-pole
plug according to markings shown below: