![background image](http://html1.mh-extra.com/html/sunbeam/20060328/20060328_service-manual_1394664014.webp)
As the temperature control is adjusted from COLD to VERY COLD, the temperature differences found between the
compressors stop and start increases. This situation occurs when the thermostat finds a temperature of 4.5±1.0°C, as a
result of the plate heating by the defrosting resistance. This model allows controlling the plate defrosting resistance when
the compressor stops during the cycle and also disconnects all the electric systems (except lighting), when it changes to
the switched off position (0). The bulb is located in the fridge evaporator plate right upper zone.
Automatic defrost models (Constant Environment – Differential: Figure B7-C)
Used in the two doors frost free models with Multiflow system and for any position of the knob (from 1 to 7); the
difference of sensed temperature between the compressor stop and start is the same. This design has been built to
evaluate the fridge environment. The bulb is located in the control box fixed in the frontal middle zone of the cooler’s
roof.
PAGE. B7
Figure B7-A: Semi – automatic / manual defrosting
models
Figure B7-B: Automatic / manual defrosting models
6
7
0
1
5
Figure B7-C: Automatic defrosting models
THERMOSTAT IN
FREEZER FRAME
THERMOSTAT IN
CONTROL BOX
TROPICALIZED FROST FREE
SPECIAL FROST FREE
REGULAR CYCLIC AND FROST FREE