THERMOSTAT REPLACEMENT
Semi – automatic / manual defrosting models (Figure B7-A)
Disconnect the electric current unit.
1. Take away all food in the compartment and defrost completely.
2. Unscrew the evaporator (of the roof or the frame, accordingly)
3. Remove the evaporator thermostat bulb.
4. Dismount the control box or the freezer frame accordingly.
5. Disconnect the thermostat electric installation.
6. Replace the damaged thermostat by a new one according to the model and the manufacturing specifications.
7. Assemble the thermostat electric installation as shown in the electric diagram in the rear part of the refrigerator.
8. Put the thermostat bulb in the corresponding place.
9. Re - assemble the control box, or the freezer frame (accordingly), in its original position.
10. Screw the evaporator again in its respective position as per the design.
Automatic / manual defrost models (Figure B7-B)
1. Disconnect the electric current unit.
2. Remove all object on the shelfs located in the fridge.
3. Unscrew the plate fastening caps rotating 90° (in the case of tropicalized frost free models take away the plate
cover previously).
4. Lift the plate softly to an angle under or 45º.
5. Remove the thermostat bulb from the plate, completely and carefully.
6. Take away the control knob and unscrew the control box.
7. Disconnect the thermostat electric installation.
8. Replace the damaged thermostat by a new one according to the model and the manufacturing specifications.
9. Assemble the thermostat electric installation as shown in the electric diagram in the rear part of the refrigerator.
10. Re - assemble the control box.
11. Put the thermostat bulb in the respective place as shown in the figure.
12. Re – locate the evaporator plate in its original position and fasten with the fixing caps.
13. In the case of tropicalized frost free models complete assemble by mounting the plate cover.
Automatic Defrost Models (Figure B7-C)
14. Disconnect the electric current unit.
15. Remove all object on the shelfs located in the fridge.
16. Take away the control knob and unscrew the control box.
17. Disconnect the thermostat electric installation.
18. Replace the damaged thermostat by a new one according to the model and the manufacturing specifications.
19. Assemble the thermostat electric installation as shown in the electric diagram located in the rear part of the
refrigerator.
20. Re – assemble the thermostat bulb as shown in the figure and screw the control box.
FORCED VENTILATION SYSTEMS IN FROST FREE MODELS.
In these models the air is impelled by a fan moving the air through the evaporator (fins or plate evaporator), to exchange
heat and cool the refrigerator’s compartments.
The motor is electrically connected to operate only if the compressor is running. It switches off during the stops
determined by the thermostat or in defrosting periods. Normally, the fan wing is rotated in clock direction (CW) to impel
air frontally, then it is sucked from the surroundings and the rear part.
The following features forced ventilation systems are included in the manufactured models: