H
Internal noise
1.
Fan helix sticking to the fin evaporator.
2.
Fan helix sticking to the cover evaporator.
3.
Waterfall sound in the rear part of refrigerator.
4.
Noise in the control.
1. Separate the helix from the evaporator.
2.
Align cover correctly.
3.
Replace suction tube and capillary
tube folding the capillary surplus outside
the refrigerator.
4.
Replace the control.
I
Refrigerator cools a little
1.
Badly regulated control
2.
Defrosting resistance working permanently.
3.
Control box light bulb on.
4.
Tubing restriction (block).
5.
Condenser dirty or covered with clothes (lack of
circulation)
6.
Inadequate location of refrigerator in the house.
7.
Refrigerator improperly or excessively used.
8.
Lack of refrigerant.
9.
Loss of refrigerant (leakages)
10. Badly placed control bulb
11. Wrong compressor.
12. Ice surplus in the freezer.
1. Adjust control as required.
2.
Check the timer operates properly.
3.
Check electric installation.
4.
Locate and eliminate obstruction.
5.
Clean and eliminate clothes in this
place.
6.
Take away the refrigerator from
places and home appliances producing
heat (stoves)
7.
Use it according to indications in the
refrigerator’s manual.
8.
Apply the recommended load.
9.
Locate the escape and re - load.
10. Put the bulb properly as indicated in
the service manual.
11. Change by the recommended
compressor.
12. Defrost frequently (push bottom)
J
Refrigerator cools too
much (1 door models)
1.
Lack of water collector tray.
2.
Badly located thermostat bulb.
3.
Badly regulated control.
1. Put tray in its position again.
2.
Put the bulb properly as indicated in
the service manual.
3.
Put control in a number lower than
present.
K
Refrigerator cools too
much (2 doors models)
1. Badly located thermostat bulb.
2.
Badly regulated control.
3.
Thermostat doesn’t disconnect.
1. Put bulb properly as shown in the
service manual.
2.
Put control in a number lower than
presently.
3.
Replace thermostat.
L
Fan motor doesn’t rotate
1. Defective motor.
2.
Motor doesn’t receive voltage
3.
Misaligned fan support.
1. Replace motor.
2. Check electric diagram/terminals
/feed cable
3.
Loosen and align this support.
M
Condensation in the
cooler roof.
1. Humidity entrance through drainages.
2.
Humidity entrance through the door.
3. Badly located thermostat bulb.
1.
Change drainage bushing.
2.
Check gasket.
3.
Put thermostat bulb properly.
MSDT-OERGE