Chapter 1
Before You Begin the Installation
3
Physical Specifications
The Sun Blade T6340 server module is approximately 12.9 x 20.1 x 1.7 inches in a 1U
form factor. The server module plugs in to a Sun Blade modular system, or
chassis
,
which provides 12V power to each module, as well as cooling through fans. In
addition to the 12V main power, the chassis provides 3.3V AUX power to each
module to power the ILOM service processor. This 3.3V AUX power enables the
chassis management module (CMM) to query each module slot prior to main power
and 12V fan application to validate that there is sufficient power and cooling to
support the modules installed in the chassis.
Environmental Requirements
TABLE 1-3
includes the environmental requirements that are specific to the Sun Blade
T6340 server module.
TABLE 1-3
Sun Blade T6340 server module
Environmental Requirements
Condition
Requirement
Operating temperature
5˚C (41˚ F) to 35˚C (95˚ F) noncondensing
Nonoperating temperature
-40˚C (-40˚ F) to 65˚C (149˚ F)
Operating humidity
10% to 90% noncondensing (27˚C (80˚ F) max. wet
bulb)
Nonoperating humidity
93% noncondensing (38˚ C (100˚ F) max. wet bulb)
Operating altitude
3048 meters (10,000’) at 35˚C (95˚ F)
Nonoperating altitude
12,000 meters (40,000’)
Содержание Sun Blade T6340
Страница 10: ...x Sun Blade T6340 Server Module Installation and Administration Guide April 2010 ...
Страница 76: ...66 Sun Blade T6340 Server Module Installation and Administration Guide April 2010 ...
Страница 82: ...72 Sun Blade T6340 Server Module Installation and Administration Guide April 2010 ...