Installing the Server Module into the
Chassis
▼
To Insert the Server Module
1. Ensure that you have the MAC address and serial number.
This information is on the customer information sheet attached to the shipping
container. The serial number is also on the front of the server module.
2. Ensure that the modular system chassis is powered on.
Refer to
“You can also use a pointed object or stylus to press and release the
recessed Power button on the server front panel.” on page 32
and to the
documentation that came with your Sun Blade modular system.
3. Locate the desired slot in the chassis.
4. Remove the filler panel from the target slot, if applicable.
5. (Optional) Attach a serial cable from the terminal server to the virtual console
connector on the dongle cable.
If you plan to use a dongle cable to connect directly to the server module, you
must connect the terminal server to the dongle cable before you insert the server
module so that you can see the boot messages for the ILOM firmware. Refer to
the sections
“Managing the Server Module With ILOM” on page 5
and
“Connecting and Configuring the Server Module” on page 12
for more
information.
a. Attach the dongle cable to the server module.
Refer to
“Attaching a Serial Console to the Server Module” on page 7
.
b. Attach a serial cable from the terminal server to the virtual console connector
on the dongle cable.
6. Position the server module vertically so that the ejectors are on the right.
Box 1 in
FIGURE 2-1
shows the server module being inserted into the chassis.