Chapter 3
Managing Disk Volumes
55
4. Verify that the device has been removed from the device tree.
Type the following command:
Note that
c1t3d0
is now
unavailable
and
unconfigured
. The corresponding
hard drive OK-to-Remove LED is lit.
5. Remove the hard drive, as described in your server module service manual.
The blue OK-to-Remove LED is extinguished when you remove the hard drive.
6. Install a new hard drive, as described in your server module service manual.
7. Configure the new hard drive.
Type the following command:
For example:
#
cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c1 scsi-bus connected configured unknown
c1::dsk/c1t0d0 disk connected configured unknown
c1::dsk/c1t1d0 disk connected configured unknown
c1::dsk/c1t2d0 disk connected configured unknown
c1::dsk/c1t3d0 disk connected unconfigured unknown
c1::dsk/c1t4d0 disk connected configured unknown
c1::dsk/c1t5d0 disk connected configured unknown
c1::dsk/c1t6d0 disk connected configured unknown
c1::dsk/c1t7d0 disk connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb0/3 unknown empty unconfigured ok
usb1/1 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
usb2/1 unknown empty unconfigured ok
usb2/2 usb-storage connected configured ok
usb2/3 unknown empty unconfigured ok
usb2/4 usb-hub connected configured ok
usb2/4.1 unknown empty unconfigured ok
usb2/4.2 unknown empty unconfigured ok
usb2/4.3 unknown empty unconfigured ok
usb2/4.4 unknown empty unconfigured ok
usb2/5 unknown empty unconfigured ok
#
#
cfgadm -c configure
Ap-Id
#
cfgadm -c configure c1::dsk/c1t3d0