Chapter 2
Installation and Configuration
17
Note –
The serial port requires the pin assignments described in
TABLE 2-1
. Note that
these are the same as the serial cable connector for the Sun Advanced Lights Out
Manager (ALOM) or Remote System Control (RSC).
4. Press Enter on the terminal device.
The connection between the terminal device and the CMM is established.
Note –
If you connect a terminal or emulator to the serial port before it has been
powered up or during its power-up sequence, you will see boot messages.
When the system has booted, the CMM ILOM software displays its login prompt:
The first string in the prompt is the default host name. It consists of the prefix
SUNCMM and the CMM ILOM MAC address. The MAC address for each service
processor is unique.
5. Log in to the CMM ILOM software:
a. Type the default user name,
root
.
b. Type the default password,
changeme
.
Once you have successfully logged in, the CMM ILOM displays its default
command prompt:
TABLE 2-1
Serial Management Port Pinouts
Pin
Signal Description
1
Request To Send (RTS)
2
Data Terminal Ready (DTR)
3
Transmit Data (TXD)
4
Ground
5
Ground
6
Receive Data (RXD)
7
Data Carrier Detect (DCD)
8
Clear To Send (CTS)
SUNCMM
nnnnnnnnnn
login: