Major Subassemblies
8-7
8
4. Seat the power supply. Push both levers up simultaneously to maintain
insertion alignment until they are fully locked (up). Use care when doing
so avoid connector damage.
Caution – Do not force the injector/ejector levers in if the power supply resists
seating in the connectors. Forcing the power supply in can damage connector
pins. Unseat the power supply, and retry by gently closing the injector/ejector
levers until the supply is fully seated.
5. Tighten the captive retaining screws.
6. Replace the EMI shield and the front panel.
Caution – Replace the EMI shield before operating the system. Sun
Microsystems Inc. is not responsible for regulatory compliance for a
SPARCserver 1000 System which is operated with the EMI panel removed.
8.4 Backplane
The backplane is located near the center of the SPARCserver 1000 behind the
front cover, EMI shield, SCSI tray, and power supply. See Figure 8-1.
8.4.1 Removal
1. Remove the front panel and EMI shield. See Chapter 7, “Internal Access.”
2. Remove the SCSI tray as described in this chapter.
3. Remove the power supply as described in this chapter.
4. Remove system board(s), air restrictor panels, and any other options that
may be installed in the four card cage slots.
!
!
Содержание SunSwift SPARCserver 1000
Страница 4: ...SPARCserver 1000 System Service Manual June 1996 ...
Страница 12: ...xii SPARCserver 1000 System Service Manual June 1996 E 5 3 Video Cables E 16 Glossary Glossary 1 ...
Страница 18: ...xviii SPARCserver 1000 System Service Manual June 1996 ...
Страница 26: ...xxvi SPARCserver 1000 System Service Manual June 1996 ...
Страница 27: ...Part1 SystemInformation ...
Страница 28: ......
Страница 39: ...Part2 Troubleshooting ...
Страница 40: ......
Страница 46: ...2 6 SPARCserver 1000 System Service Manual June 1996 2 ...
Страница 77: ...Part3 PreparingforService ...
Страница 78: ......
Страница 89: ...Part4 SubassemblyRemovaland Replacement ...
Страница 90: ......
Страница 108: ...8 10 SPARCserver 1000 System Service Manual June 1996 8 ...
Страница 125: ...Part5 SystemBoard ...
Страница 126: ......
Страница 153: ...Part6 IllustratedPartsBreakdown ...
Страница 154: ......
Страница 162: ...12 8 SPARCserver 1000 System Service Manual June 1996 12 ...
Страница 163: ...Part7 Appendixes Glossary Index ...
Страница 164: ......
Страница 216: ... 6 SPARCserver 1000 System Service Manual June 1996 ...