Software Issues
47
Cannot Install RHEL4 U3 (32-Bit) to Sun Fire
X4200 if QLogic PCI Card is Already Installed in
PCI Slots 1, 3, or 4 (6437504)
If your Sun Fire X4200 server has a QLogic PCI card installed in PCI slots 1, 3, or 4
and you then try to install RHEL4 U3 (32-bit), installation fails at the time the
anaconda
script starts. There are no other warning or error messages. See
for the PCI slot locations.
Workaround
This failure does not occur if the QLogic card is installed in PCI slots 0 or 2. Failures
do not occur if a QLogic card is installed in PCI slots 1, 3, or 4
after
RHEL4 U3 (32-
bit) is installed. The Kudzu utility finds and properly configures the card and the
system operates as expected.
Server Might Reboot Sun Fire X4100 Server when
MTU is Set to 9K on Kirkwood Interface (6335741)
The Sun Fire X4100 server might spontaneously reboot when running network traffic
over the Kirkwood interface, in a Linux environment. This problem has only been
observed when the MTU is set to 9K.
Workaround
None.