This section describes known problems and associated workarounds on Sun Fire
X4100 and Sun Fire X4200 servers for RHEL operating system and the SLES.
Hard-Disk Drive Display Omits Disk Listing At
Installation When Multiple SCSI disks Are
Attached to System on RHEL4 U4 (6447738)
The hard-disk drive display omits a disk listing during installation if there are many
SCSI disks attached to a system. Not all disks are available during the installation.
In addition, the disk-drive display lists the wrong drive type after the installation.
Workaround
None. However, to display the omitted hard-disk drive, use one of the following
instructions:
■
During installation, disconnect all external storage devices
except
those devices
needed for disk initialization.
■
Perform manual disk-initialization after you reboot the system, when all disks are
available.
Duplicate Devices Seen by Linux OS if External
RAID Array Connects to Server Through Ultra320
SCSI (6220406)
If a RAID array is attached to the system using a Sun StorEdge PCI/PCI-X Single
Ultra320 SCSI host bus adapter (Ultra320 SCSI), you might see the following if you
enter the command,
fdisk -l
,
depending on which Linux OS you are using:
■
Duplicate devices for each logical unit number (LUN) in the array
■
One device for multiple LUNs in the array
Содержание Sun Fire X4100
Страница 10: ...x Sun Fire X4100 and Sun Fire X4200 Servers Product Notes November 2006...
Страница 14: ...xiv Sun Fire X4100 and Sun Fire X4200 Servers Product Notes November 2006...
Страница 18: ...4 Sun Fire X4100 and Sun Fire X4200 Servers Product Notes November 2006...
Страница 70: ...56 Sun Fire X4100 and Sun Fire X4200 Servers Product Notes November 2006...
Страница 78: ...64 Sun Fire X4100 and Sun Fire X4200 Servers Product Notes November 2006...
Страница 80: ...66 Sun Fire X4100 and Sun Fire X4200 Servers Product Notes November 2006...