62
Sun Fire X4100 and Sun Fire X4200 Servers Product Notes • November 2006
Preventative Maintenance Issue
Heatsinks and Fans Can Become Clogged
System cooling might be affected by dust and contaminant build-up. Therefore, you
should open and check systems approximately every six months (or more often in
dirty operating environments). Check system heatsinks, fans, and air openings. If
necessary, clean systems by carefully brushing, blowing, or vacuuming contaminants
from the system.
Hard-Disk Drive (HDD) Issues
Do not Mix HDD Capacities When Using RAID
You cannot use RAID if your Sun Fire X4100 or Sun Fire X4200 server contains hard-
disk drives with differing capacities (for example, a 36-GB drive in the same server
with a 73-GB drive).
Note –
You
can
mix drives with differing capacities if you are not using RAID.
Workaround
None. This is expected behavior.