LSI Firmware, Service Processor, and BIOS Issues
23
You must use the BIOS Configuration Utility to reset the date and time and load
optimal defaults after these system events:
■
When a pre-release version of the server with a pre-release version of the
firmware such as version 6169, has the firmware upgraded to the release version
6464.
■
When the BIOS checksum is invalid.
■
When the CMOS is cleared using the Clear CMOS jumper or using IPMItool
through the service processor.
Workaround
After any of the events listed above happen, use the BIOS Configuration Utility to
reset the date and time and to load the optimal defaults:
1. Enter the BIOS Configuration Utility by pressing F2 while the system is booting.
2. Change the date and time on the Main menu screen of the utility.
3. Use the arrow keys to choose Load Optimal Defaults on the Exit menu.
4. Press Enter to go to the next screen.
5. Press Enter when prompted to load the optimal defaults.
6. Choose Save Changes and Exit, and then press Enter.
7. Press Enter when prompted to save the configuration changes and exit the utility.