Sun StorEdge Expansion Cabinet Installation and Service Manual • July 2000
4.2
Safety Requirements
■
Ensure that the voltage and frequency of the power outlet to be used matches the
electrical rating labels on the cabinet.
■
Wear an antistatic wrist strap when handling any magnetic storage devices or
system boards.
■
Use only properly grounded power outlets.
Caution –
Do not make mechanical or electrical modifications to the cabinet.
Sun Microsystems is not responsible for regulatory compliance of modified cabinets.
4.3
Installing a Device
These instructions are meant to be used in conjunction with those that shipped with
the device you are installing. Read both procedures before beginning the installation.
Note –
You may need to remove the side panels from the cabinet. If so, also perform
the steps in Section 4.5 “Side Panel Removal and Replacement” on page 4-7.
1. Determine where you are going to install the device.
Refer to the online Rackmount Placement Matrix.
2. Open the rear door.
3. For cabinets equipped with a front screen door, open the front screen door.
If you want to remove the door:
a. Reach inside of the door and push down on the lever attached to the spring of
the top hinge pin.
This will cause the hinge pin to retract into the door.
b. Tilt the door out from the top mounting bracket.
c. Remove the door and set it aside.