Chapter 2
Hardware Installation
2-17
Note –
A single 10/100BASE-T Ethernet port is also available on the Sun Netra
CP3060 RTM when installed.) Refer to the
Sun Netra CP3060 Rear Transition Module
User’s Guide
(819-6689) for more information.
Use the
bge
device names shown in
when configuring the Ethernet
ports.
■
An asynchronous serial I/O cable can be attached from serial communication
devices to the RJ-45 serial port on the Sun Netra CP3060 blade server’s front
panel.
Note –
A serial port is also provided on the Sun Netra CP3060 RTM. Either the
serial port on the Sun Netra CP3060 blade server or the serial port on Sun Netra
CP3060 RTM can be used, but only one of the ports should be used at one time.
Once a serial cable is connected, use the
tip
utility on the host to establish a
full-duplex terminal connection with the Sun Netra CP3060 blade server. At the
UNIX prompt in a command tool or shell tool, type:
2.7
Installation of Optional AMC Modules
An Advanced Mezzanine card (AMC) is a card or module that provides additional
functionality to the Sun Netra CP3060 blade server. The blade server contains one
AMC slot in which you can install an optional AMC device (see
for the
location of these slots). The AMC device can be installed and removed via a cutout
in the front panel while the Sun Netra CP3060 blade server is installed in the chassis.
TABLE 2-2
bge
Device Names
Ethernet Ports
Solaris 10 OS
Ethernet Port A (on front panel) and
Ethernet port on the RTM
e1000g0
Ethernet Port B (on front panel)
e1000g1
TABLE 2-3
#
tip -9600 /dev/ttya
(for serial port)
Содержание Netra CP3060
Страница 48: ...2 20 Netra CP3060 Board User s Guide April 2009...
Страница 49: ...Chapter 2 Hardware Installation 2 21...
Страница 79: ...4 22 Netra CP3060 Board User s Guide April 2009...
Страница 107: ...5 28 Netra CP3060 Board User s Guide April 2009...
Страница 129: ...Index 4 Netra CP3060 Board User s Guide April 2009...