Chapter 3
Removing and Replacing Hot-Swappable Components
49
Installing a Hard Drive
The system’s drive hot-swap feature enables you to insert a hard drive without
shutting down the operating system or turning off the system power. When
installing a drive, you must insert the hard drive and wait for it to spin up to
operating speed. Then you re-create or reconfigure the file systems so that the Solaris
OS recognizes the hard drive. Finally, you configure your application (if necessary)
to operate with this new drive.
Use the
cfgadm
command to install a Netra 440 server’s internal hard drives using
the hot-swap operation. The following procedure describes the general steps
involved, but your specific device names might be different.
The following procedure assumes that you are accessing the system console by the
default method of connecting to the serial management port (SERIAL MGT) of the
Netra 440 server.
Caution –
Do not hot-swap drives without the correct preparations. The system
supports hot-swapping hard drives, but you must issue a software command before
you remove or install a hard drive.
1. Open the system door.
2. Release the hard drive handle on the hard drive.
Pinch the hard drive latch to open the handle.
3. Align the hard drive to its drive bay.
Orient the hard drive so that the hard drive latch is on the bottom.
Note –
If you are replacing a drive that you removed previously, be sure to install
the hard drive into the same drive bay from which it was removed.
4. Insert the hard drive into the hard drive bay guide rails.
Slide the hard drive into the bay until it barely contacts the backplane.
5. Firmly press the center of the hard drive handle toward the hard drive until the
latch closes, securing the hard drive in place.
6. Log in as superuser:
%
su
Password:
#
Содержание Netra 440
Страница 12: ...x Netra 440 Server Service Manual August 2004...
Страница 18: ...xvi Netra 440 Server Service Manual August 2004...
Страница 52: ...34 Netra 440 Server Service Manual August 2004...
Страница 106: ...88 Netra 440 Server Service Manual August 2004 FIGURE 4 24 Removing the Screw for a Long PCI Card...
Страница 150: ...132 Netra 440 Server Service Manual August 2004...
Страница 160: ...142 Netra 440 Server Service Manual August 2004...
Страница 166: ...148 Netra 440 Server Service Manual August 2004 U USB ports description 17 location 12 17 pinouts 125 user alarm LED 11...