40
Netra 440 Server Service Manual
• August
2004
The following procedure assumes that you are accessing the system console by the
default method of connecting to the serial management port (SERIAL MGT) of the
Netra 440 server.
The part number for a DC power supply is F300-1567, and the part number for an
AC power supply is F300-1674.
Removing a Power Supply
If a power supply fails, the enclosure status Service Required LED and that power
supply Service Required LED will light.
Caution –
If a power supply fails and you do not have a replacement available,
leave the failed power supply installed to ensure proper system cooling.
Caution –
Power supply hot-swap operations should only be conducted by
qualified service personnel.
Caution –
Attempting to remove a power supply without issuing a software
command to isolate it could damage the power supply.
Caution –
You have limited time to perform the power supply hot-swap operation.
You have 10 minutes at sea level and a maximum of 7 minutes at 10,000 feet (3048
meters) to ensure proper system cooling. Ensure that you have a replacement power
supply ready before beginning this procedure.
1. Attach the antistatic wrist strap.
See
Содержание Netra 440
Страница 12: ...x Netra 440 Server Service Manual August 2004...
Страница 18: ...xvi Netra 440 Server Service Manual August 2004...
Страница 52: ...34 Netra 440 Server Service Manual August 2004...
Страница 106: ...88 Netra 440 Server Service Manual August 2004 FIGURE 4 24 Removing the Screw for a Long PCI Card...
Страница 150: ...132 Netra 440 Server Service Manual August 2004...
Страница 160: ...142 Netra 440 Server Service Manual August 2004...
Страница 166: ...148 Netra 440 Server Service Manual August 2004 U USB ports description 17 location 12 17 pinouts 125 user alarm LED 11...