134
Netra 440 Server Service Manual
• August
2004
Electrical Specifications
AC Operating Power Limits and Ranges
The information in this section applies to the AC version of the Netra 440 server.
gives AC power source requirements for each power supply in the Netra
440 server, and
gives AC power source requirements for the Netra 440
server as a whole.
Note –
The figures for the maximum operating current are provided to help you
specify the fusing and cabling you need to deliver power to your equipment.
However, these figures represent worst-case scenarios.
TABLE
C-2
AC Operating Power Limits and Ranges for Each Power Supply in the Netra
440 Server
Description
Limit or Range
Operating input voltage range
90 - 264 VAC
Operating frequency range
47 - 63 Hz
Maximum operating input current
5.5 A @ 90 VAC
Maximum operating input power
500 W
TABLE
C-3
AC Operating Power Limits and Ranges for the Netra 440 Server
Description
Limit or Range
Operating input voltage range
90 - 264 VAC
Operating frequency range
47 - 63 Hz
Maximum operating input current
11 A @ 90 VAC
Maximum operating input power
1000 W
Содержание Netra 440
Страница 12: ...x Netra 440 Server Service Manual August 2004...
Страница 18: ...xvi Netra 440 Server Service Manual August 2004...
Страница 52: ...34 Netra 440 Server Service Manual August 2004...
Страница 106: ...88 Netra 440 Server Service Manual August 2004 FIGURE 4 24 Removing the Screw for a Long PCI Card...
Страница 150: ...132 Netra 440 Server Service Manual August 2004...
Страница 160: ...142 Netra 440 Server Service Manual August 2004...
Страница 166: ...148 Netra 440 Server Service Manual August 2004 U USB ports description 17 location 12 17 pinouts 125 user alarm LED 11...