Netra 440 Server Service Manual
• August
2004
Initiating a Reconfiguration Boot
After installing any new internal option or external storage device, you must
perform a reconfiguration boot so that the operating system is able to recognize the
newly installed device(s). In addition, if you remove any device and do not install a
replacement device prior to rebooting the system, you must perform a
reconfiguration boot in order for the operating system to recognize the configuration
change. This requirement also applies to any component that is connected to the
system I
2
C bus to ensure proper environmental monitoring.
This requirement
does not
apply to any component that is:
■
Installed or removed as part of a hot-swap operation
■
Installed or removed before the operating system is installed
■
Installed as an identical replacement for a component that is already recognized
by the operating system
To issue software commands, you need to set up an alphanumeric terminal
connection, a local graphics monitor connection, ALOM connection, or a TIP
connection to the Netra 440 server. See the
Netra 440 Server Installation Guide
(817-
3882-xx) for more information about connecting the Netra 440 server to a terminal or
similar device.
Caution –
Before you power on the system, ensure that the system doors and all
panels are properly installed.
This procedure assumes that you are accessing the system console using the serial
management or network management port.
For more information, refer to the
Netra 440 Server Administration Guide
(817-3884-
xx).
1. Turn on power to any external peripherals and storage devices.
Read the documentation supplied with the device for specific instructions.
2. Turn on power to the alphanumeric terminal or local graphics monitor, or log in to
the ALOM.
3. Turn the rotary switch to the Diagnostics position (
Use the Diagnostics position to run POST and OpenBoot Diagnostics tests to verify
that the system functions correctly with the new part(s) you just installed.
4. Press the On/Standby button to power on the system.
Содержание Netra 440
Страница 12: ...x Netra 440 Server Service Manual August 2004...
Страница 18: ...xvi Netra 440 Server Service Manual August 2004...
Страница 52: ...34 Netra 440 Server Service Manual August 2004...
Страница 106: ...88 Netra 440 Server Service Manual August 2004 FIGURE 4 24 Removing the Screw for a Long PCI Card...
Страница 150: ...132 Netra 440 Server Service Manual August 2004...
Страница 160: ...142 Netra 440 Server Service Manual August 2004...
Страница 166: ...148 Netra 440 Server Service Manual August 2004 U USB ports description 17 location 12 17 pinouts 125 user alarm LED 11...