▼
How to Connect to the Server Using the Server’s IP
Address
Note –
This procedure assumes that you have connected the server to your network through an
Ethernet cable.
If you have not already done so, determine the service processor’s IP address:
a. Power on main power by pressing the Power button on the front panel.
b. Start the BIOS Setup utility by pressing the F2 key while the system is performing the
power-on self-test (POST).
c. When the BIOS Main menu screen is displayed, select Advanced.
d. When the Advanced screen is displayed, select IPMI 2.0 Configuration.
When the IPMI 2.0 Configuration screen is displayed, select the LAN Configuration menu
item.
e. Select the IP Address menu item.
The service processor’s IP address is displayed using the following format:
Current IP
address in BMC: xxx.xxx.xxx.xxx
Using a client system, establish a Secure Shell (SSH) connection to the service processor’s IP
address:
ssh -l root
sp_ip_address
Log in to the service processor as an administrator, for example:
login:
root
password:
changeme
Start the ILOM console mode by typing the following:
start /SP/console
Note –
If you have changed the SP Serial Port default settings, make sure you reset them to the
default settings.
Only accounts with Administrator privileges are enabled to configure the SP serial port. See the
Integrated Lights-Out Manager (ILOM) 3.0 documentation.
Follow the onscreen prompts.
Before You Begin
1
2
3
4
5
Installation Worksheet
Sun Fire X4800 Server Installation Guide • —12, March 2011
110
Содержание Fire X4800
Страница 1: ...Sun Fire X4800 Server Installation Guide Part No 821 0285 12 March 2011...
Страница 5: ...Index 139 Contents 5...
Страница 6: ...6...
Страница 14: ...14...
Страница 20: ...20...
Страница 37: ...6 152mm Installing the Server In a Rack Using the Standard Rack Mounting Kit 37...
Страница 57: ...1 2 3 Installing the Server in a Rack Using the Universal Rack Mounting Kit 57...
Страница 65: ...1 2 3 Installing the Server in a Rack Using the Universal Rack Mounting Kit 65...
Страница 73: ...6 152mm Installing the Server in a Rack Using the Universal Rack Mounting Kit 73...
Страница 75: ...1 1 2 2 Installing the Server in a Rack Using the Universal Rack Mounting Kit 75...
Страница 84: ...84...
Страница 87: ...6 152mm Removing the Server From the Rack 87...
Страница 93: ...Figure Legend 1 Video console 2 Serial console 3 USB 2 connectors Attaching Administration SP Cables 93...
Страница 100: ...100...
Страница 102: ...102...
Страница 124: ...124...
Страница 142: ...142...