Summit Ice Melt Systems
PO Box 6928, Tahoe City, CA 96145
Ph: 530-583-8888 Fax: 530-583-7777
www.SummitIceMelt.com
4.
If applicable, continue tracing up one side of Valley Base and
return down other side of base. It maybe helpful to temporarily
remove the adjacent mitered HotSlot Panel to insert and twist the
Heater Cable. Re-install.
5.
Be sure to leave a drip loop at components so that water will not
track down the heating cable into the component. Install the
heating cable using the Layout Drawings provided.
6.
Be sure to leave enough heating cable to connect to the junction
box.
7.
Be sure to leave drip loops where appropriate.
8.
Be sure to loop and secure the heating cable at the bottom of
downspouts so that the heating cable is not exposed to mechanical
damage. Use protective downspout brackets for heating cable.
9.
Use UV resistant heating cable ties whenever two heaters are
intended to stay together.
10.
Visually inspect the heating cable for mechanical damage and test
the entire circuit for insulation resistance prior to applying power.
(See Electrical Hookup, page 17).
When installing the heating cable:
•
Do not pull it over sharp edges.
•
Do not use excessive pulling force.
•
Do not kink or the crush heating cable.
•
Do not walk on the heating cable.
•
Protect heating cable from sharp edges, such as sheet metal
covers, with electrical tape.
WARNING: Shock and fire hazard.
Damaged heating cable or
components can cause electrical shock, arcing, and fire. Do not attempt to
energize damaged heating cable or components. Replace them
immediately using a new length of heating cable and the appropriate
accessory.