![Summit Radiant Edge HotSlot Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/summit/radiant-edge-hotslot/radiant-edge-hotslot_installation-and-operation-manual_1391512014.webp)
WARNING:
Taping heating cable ends is NOT acceptable.
Summit Ice Melt Systems
PO Box 6928, Tahoe City, CA 96145
Ph: 530-583-8888 Fax: 530-583-7777
www.SummitIceMelt.com
Heating Cable Installation (Cont’d.)
1.
Once the HotSlot and Valley Base Panels have been installed and
adhesives cured, if applicable, the heating cable is ready for
installation.
2.
Follow the heating cable Power Connection Kit instructions, and
install the End Seal as directed. The End Seal will protrude beyond
the HotSlot Panel. End Seal may be better concealed if folded
down under the Panel and affixed to the fascia.
3.
Start with the heating cable end terminated with the End Seal.
Leave the End Seal beyond the edge of the roof and work your way
back to the other end of the system per the Layout Drawings. Press
the heater cable into the slot behind the drip edge. Ensure cable is
seated completely into the slot. See Figure C.
Radiant Edge HotSlot Figure C
Page 13 of 29