![Sumitomo CYCLO Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/sumitomo/cyclo/cyclo_maintenance-manual_1390636085.webp)
83
Application
Product
(3) Limit Switch Specifications
Table 11-1 Model
Products of OMRON Corporation.
Signal
Rotation Direction
Right or Left
Reversible Direction
Main motor OFF
Z−15GQ22−B (1 piece)
Submotor or alarm ON
Z−15GQ−B (1 piece)
Z−15GQ−B (2 pieces)
Auxiliary signal
Z−15GQ−B (1 piece)
Please consult with us.
Table 11-2 Rating
Rated Voltage
(V)
Noninductive Load (A)
Inductive Load (A)
Resistance Load
Lamp Load
Inductive Load
Motor Load
Normally
Closed Circuit
Normally
Open Circuit
Normally
Closed Circuit
Normally
Open Circuit
Normally
Closed Circuit
Normally
Open Circuit
Normally
Closed Circuit
Normally
Open Circuit
AC 125
250
500
15
15
10
3
2.5
1.5
1.5
1.25
0.75
15
15
6
5
3
1.5
2.5
1.5
0.75
DC 8
14
30
125
250
15
15
6
0.5
0.25
3
3
3
0.5
0.25
1.5
1.5
1.5
0.5
0.25
15
10
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03
Table 11-3 Contact Point Specification
Inrush Current
Normally Closed Circuit Normally Open Circuit
Max. 30A
Max. 15A
Note : 1. Values shown in the table indicate steady-state current.
2. An inductive load is a power factor of 0.4 (AC) or more, or a time constant of 7 ms (DC) or less.
3. A lamp load is a load with an inrush current 10 times as high.
4. A motor load is a load with inrush current 6 times as high.
5. Working ambient temperature: General type -25 to 80
℃
(no ice)
Working ambient humidity: General type 35 to 85%RH (no condensation)
(4) Example of How to Connect a Spring-Loaded Limit Switch (2-Point Signal, Dual Safety, Reversible Rotation)
11. Wiring
Note : 1. Limit switches LS, LS
F
and LS
R
surrounded by
are built-in on CYCLO Drive with torque limiter other devices should be
supplied by customer.
2. If there is an overload, LS
F
(LS
R
) and LS operate in order.
3. Devices within are
not required for 1-point signals.
M …… Motor
MC
F
… Electromagnetic switch for forward motor rotation
MC
R
… Electromagnetic switch for reverse motor rotation
BS
F
… Pushbutton switch for forward rotation
BS
R
… Pushbutton switch for reverse rotation
BS
ES
… Pushbutton switch for stopping
THR … Thermal relay
LS …… Limit switch (for forward, reverse and stop)
LS
F
… Limit switch (for forward alarm)
LS
R
… Limit switch (for reverse alarm)
KS … Knife switch
TR … Motor timer
F …… Fuse
BL … Alarm
CYCLO Drive with Torque Limiter
E
E
E
E
MC
F
MC
R
THR
LS
TR
BS
F
MC
F
MC
R
BS
R
MC
F
MC
R
E
BS
ES
F
LS
F
LS
R
MC
F
MC
R
KS
TR
TR
BL
(ON. Delay)
R
S
M
MC
F
MC
R
THR
R
S
T