ECO ARC 600
5-3
Revision 1/10/08
Pos.
Description
Function
1
Signal lamp white
Permant
= System ON
Blinking
= Emergency stop
2
Signal lamp green
System ready
3
Signal lamp yellow
Reset-button
Permanent
= Error Overload
Blinking
= Error Temp. or Air
4
Wire feed button
Wire feed without spray voltage, without atomizing air
5
Ammeter
Indicator spray current
6
Main switch
Power supply On / Off
7
Step switch wire feed
Regulates wire feed (s. Changing spray capacity)
8
Step switch for spray voltage
Regulates spray voltage (s. Setting-up spray voltage)
9
Manometer
Indicator pressure of atomizing air
10
Pressure regulator
Regulates pressure of atomizing air
11
Wire pressure lever
Relieves tension of wire feed rolls
12
Knurled screws
Locking of wire guide tubes
13
Oiler Air motor
Reservoir for greasing the air motor
14
Drain valve
Filters water and dirt particles out of the compressed air
A
On / Off button
Starts / Stopps the spray process
B
Dead man’s switch
Must be held while spraying
C
Adjustment screw (at exhaust
throttle)
Regulates the spray current
Содержание ECO ARC 600
Страница 6: ......
Страница 47: ...ECO ARC 600 5 1 Revision 1 10 08...
Страница 74: ...ECO ARC 600 7 6 Revision 1 10 08...
Страница 75: ...ECO ARC 600 8 1 Revision 1 10 08...
Страница 88: ...ECO ARC 600 8 14 Revision 1 10 08 T2 K1 A10 F4 D10 F2 1 F2 2 F3 K3 F21 F22 F23...
Страница 94: ...ECO ARC 600 9 2 Revision 1 10 08 9 2 Circuit diagram...