ECO ARC 600
6-11
Revision 1/10/08
6.5
Electric arc shuts off, spray wires not feeding, push gear running
Indication
Cause
Remedy
Power supply
Solenoid valve defective.
(Comp. air - air motor)
Spray device:
Push OFF-button.
Unscrew compressed air
hose of power supply.
Spray device:
Push ON-button.
If no air is blowing at the
compressed air hose con-
nection - replace solenoid
valve.
Spray device
Air motor defective
Compressed air is leaking:
Demount air motor and put
for repair.
(s. maintenance)
Hose package
Air motor hose defective
Replace air motor hose
or put for repair.
ON OFF ON
System OFF
Error Overload
Содержание ECO ARC 600
Страница 6: ......
Страница 47: ...ECO ARC 600 5 1 Revision 1 10 08...
Страница 74: ...ECO ARC 600 7 6 Revision 1 10 08...
Страница 75: ...ECO ARC 600 8 1 Revision 1 10 08...
Страница 88: ...ECO ARC 600 8 14 Revision 1 10 08 T2 K1 A10 F4 D10 F2 1 F2 2 F3 K3 F21 F22 F23...
Страница 94: ...ECO ARC 600 9 2 Revision 1 10 08 9 2 Circuit diagram...