ECO ARC 600
4-4
Revision 1/10/08
4.5.2 Drum decoiling device
•
Assemble all components of drum decoiling device as shown
below..
4.6
Important notes to follow:
4.6.1 Hasp / dorn spools
•
The wire must be fed from the top of the spool into the wire guide
tubes.
•
The wires must not touch each other.
There is danger of short-circuit!
•
Check all wire guidings for smooth and easy running.
4.6.2 Drum decoiling device
•
Ensure sufficient clearance of steel drums.
There is a danger of short-circuit!
•
Look out for metal dust bridges.
There is a danger of short-circuit!
•
Do not place drums on conductive floors such as steel plates.
There is a danger of short-circuit!
•
The wires must not touch each other.
There is danger of short-circuit!