ECO ARC 600
6-5
Revision 1/10/08
6.3
System cuts out
Indication
Cause
Remedy
Three phase
current
Plug / connections are loose.
or
Wrong power / power failure
Check plug / connections
Check mains power
Fuse
Check fuse at three phase
current power supply
Three phase
current
Fluctuations in mains power
Check mains power, if
necessary install separate
line
Compressed air
supply
Cross-section of pipe is too
small
Volumetric flow (Nm³ / h) too
low
Required cross-section of
compressed air supply:
min. 20 mm (3/4’’) max. 10 m
better 25 mm (1’’)
Check filter insert in drain
valve; clean or replace
OFF OFF OFF
ON OFF ON
System OFF
Error Overload
ON OFF BLINKING
System OFF
Error Air
Содержание ECO ARC 600
Страница 6: ......
Страница 47: ...ECO ARC 600 5 1 Revision 1 10 08...
Страница 74: ...ECO ARC 600 7 6 Revision 1 10 08...
Страница 75: ...ECO ARC 600 8 1 Revision 1 10 08...
Страница 88: ...ECO ARC 600 8 14 Revision 1 10 08 T2 K1 A10 F4 D10 F2 1 F2 2 F3 K3 F21 F22 F23...
Страница 94: ...ECO ARC 600 9 2 Revision 1 10 08 9 2 Circuit diagram...