Section 5
MAINTENANCE AND TROUBLESHOOTING
27
5.4D TROUBLESHOOTING --- DS---13 (Continued)
SYMPTOM/MESSAGE
PROBABLE CAUSE
REMEDY
T2 HI (continued)
Intercooler Tube Bundle Fouled
Cleanse tube hundle. If fouling
persists, then provide cleaner
cooler water.
Discharge Check Valve Leaking
Refer to compressor’s Operators Manual
for check valve maintenance.
Inlet Throttling Valve Not Fully Open
See inlet valve adjustment.
Inlet Air Filter Clogged
Refer to compressor’s Operators Manual
for filter maintenance.
Line Pressure is Too High
Reset Supervisor unload pressure.
Temperature Transducer Failure
Check connection from trans---
ducer. If adequate, replace
transducer.
P1 HI
Exceeded P1 MAX for Pre---Alarm
Exceeded P1 MAX for Shutdown
Exceeded P2 MAX for Shutdown
Pressure Transducer Failure
Check connection from trans---
ducer. If adequate replace
transducer.
P2 HI
Exceeded P2 MAX for Pre---Alarm
Exceeded P2 MAX for Shutdown
Blowdown Valve Failed to
Refer to compressor’s Operator’s Manual
Actuate
for blowdown valve maintenance.
Solenoid Valve Controlling Blowdown
Valve Failed to Operate
Refer to compressor’s Operator’s Manual
for solenoid valve maintenance.
Control Air Filter Clogged
Refer to compressor’s Operator’s Manual
for control filter maintenance.
COMPRESSOR DOES NOT
BUILD FULL DISCHARGE
PRESSURE
Air Demand Exceeds Supply
Check air service lines for open
valves or leaks.
Inlet Air Filter Clogged
Check for maintenance message
on Supervisor
II
display. Change
element.
Inlet Air Valve Not Fully Open
Check actuation and butterfly disc
position.
Transducer P2 Malfunction
Check connections from trans---
ducer. If adequate, replace trans---
ducer.
Blowdown Valve Leaking
Refer to compressor’s Operator’s manual
for blowdown valve maintenance.
Air End(s) Malfunctioning
Consult Sullair Service Department.
LINE PRESSURE RISES ABOVE
UNLOAD SETTING
Blowdown Valve Failed to
Refer to compressor’s Operator’s Manual
Activate
for blowdown valve maintenance.
Solenoid Valve Controlling Blowdown
Refer to compressor’s Operator’s Manual
Valve Failed to Operate
for solenoid valve maintenance.
Transducer P2 Malfunction
Check connections from transducer.
If adequate, replace transducer.
Control Air Filter Clogged
Refer to compressor’s Operator’s Manual
for control filter maintenance.
Содержание Supervisor II
Страница 1: ...SUPERVISOR Part Number 02250071 398 eSullair Corporation INSTRUCTION MANUAL II ALL MODELS ...
Страница 6: ...Section 1 SAFETY 2 Figure 1 1 Decals ...
Страница 7: ...Section 2 SUPERVISOR II DESCRIPTION 3 Figure 2 1 Supervisor II Panel All Models Except DS 13 ...
Страница 8: ...Section 2 SUPERVISOR II DESCRIPTION 4 Figure 2 1A Supervisor Panel DS 13 ...
Страница 18: ...14 NOTES ...
Страница 22: ...18 NOTES ...
Страница 24: ...20 NOTES ...