Section 3
COMPRESSOR OPERATION
15
3.1 STANDARD PARAMETER SETUP
Pressing the program key enters parameter dis-
play and edit mode. To move to the next parameter
press the program key. To increment a parameter
press the up arrow key or logo key. The logo key
will increment by 10. To decrement the value press
the down arrow key.
The parameters are displayed in the following or-
der:
S
Unload pressure --- The pressure where
the machine is unloaded. For example if
this parameter is set to 110 PSI (7.6 bar)
the machine will unload when the line pres-
sure is above 110 PSI (7.6 bar).
UNLOAD
100 PSI
S
Load differential --- The pressure differ-
ential below the unload pressure where the
machine is loaded. For example if the un-
load pressure is set to 110 PSI (7.6 bar)
and the load differential is set to 10 PSID
(0.7 bar), the machine will load when the
line pressure goes below 100 PSI (6.9 bar).
LOAD
10 PSI
S
P1 Max --- Maximum sump pressure. An
alarm and shut down will occur when the
sump pressure rises above this pressure.
P1 MAX
135 PSI
S
Wye to delta transition timer --- For full
voltage starters this parameter is set to 0.
WYE DELT
10 SEC
S
Restart time --- Time to wait after powerup
before starting machine. This parameter is
used to keep several machines from start-
ing at the same time after power up, or to
delay start until other equipment is started.
If disabled the machine will not automati-
cally start after power up.
RST TIME
10 SEC
S
Unload Stop Timer --- If the machine is
running in AUTO mode, this parameter
specifies the ammount of time that the ma-
chine will run unloaded before shutting off.
If the time is set less than 15 minutes (for
example 5), there may be times when the
machine will run unloaded for more than 5
minutes. This is because there is another
timer that keeps the machine from being
started more than four times an hour.
UNLD TIM
15 MIN
S
Language select --- English, German,
Spanish, Italian and French may be se-
lected for display language.
LANGUAGE
ENGLISH
S
Units --- English or metric units may be se-
lected.
UNITS
ENGLISH
S
Communications ID # --- This is the net-
work address of a machine. If there is more
that one machine connected to the net-
work, each machine must have a unique
number
COM ID #
1
S
Communications baud rate --- This
should always be selected to 9600 baud
for all sequencing modes. It may be lower
for slave or monitoring modes.
BAUDRATE
9600
3.2 DELUXE PARAMETER SETUP
The following parameters are only available on de-
luxe model Supervisor
II
.
S
Sequence method --- This parameter sets
the method used for sequencing. The
choices are DISABLED, REMOTE, SLAVE,
HOURS, COM ID#. See the Sequencing &
Protocol Manual (P/N 02250057---696) for
details about these modes.
SEQUENCE
HOURS
Содержание Supervisor II
Страница 1: ...SUPERVISOR Part Number 02250071 398 eSullair Corporation INSTRUCTION MANUAL II ALL MODELS ...
Страница 6: ...Section 1 SAFETY 2 Figure 1 1 Decals ...
Страница 7: ...Section 2 SUPERVISOR II DESCRIPTION 3 Figure 2 1 Supervisor II Panel All Models Except DS 13 ...
Страница 8: ...Section 2 SUPERVISOR II DESCRIPTION 4 Figure 2 1A Supervisor Panel DS 13 ...
Страница 18: ...14 NOTES ...
Страница 22: ...18 NOTES ...
Страница 24: ...20 NOTES ...