Section 5
MAINTENANCE AND TROUBLESHOOTING
24
5.4B --- TROUBLESHOOTING GUIDE --- LS---12; LS---16; LS---20; LS---20S; LS---25 and EUROPE (Continued)
SYMPTOM
PROBABLE CAUSE
REMEDY
LINE PRESSURE RISES ABOVE
UNLOAD SETTING
Pressure Sensor P2 at Fault
Check connections from trans---
ducer. If adequate, replace
transducer.
Unloading Device (i.e., Blowdown
Check operation of unloading device
Valve, Sullicon Actuator, Optional
Spiral Valve) Failed to Operate
Solenoid Valve Failed
Check operation of solenoid valve.
to Operate
Control Air Signal Leaks
Check tubework feeding control signal
for leaks.
Control Air Signal Filter Clogged
See compressor Operator’s Manual for filter
assembly service.
EXCESSIVE FLUID CONSUMPTION
Clogged Return Line Strainer or Orifice
Clean strainer --- screen an o --- ring replacement
kit available. Clean orifice.
Damaged or Improperly Gasketed
Separator Elements
Inspect separator elements and gaskets.
Replace if damaged.
Fluid System Leaks
Check tube/pipework for leaks.
Fluid Level Too High
Drain excess fluid.
Excessive Fluid Foaming
Drain and change fluid.
5.4C TROUBLESHOOTING GUIDE --- LS---16T & LS---20T
SYMPTOM
PROBABLE CAUSE
REMEDY
T1 HI, T2 HI Message
Discharge Temperature Exceeded
255˚ F (124˚ C) for Pre---Alarm
Discharge Temperatur Exceeded
265˚ F (129˚ C) for Shutdown
Ambient temperature exceeded
Improve local ventilation (i.e.,
105
_
F (41
_
C)
remote intake of process and/or
cooling air.
Fluid Level in Sump is Too Low
Check/correct fluid level.
Thermal Valve Malfunctioned
Check/replace thermal valve.
Cooler Fins are Dirty
Clean cooler fins.
Water Flow is Low (water---cooled
Check cooling water supply (i.e.,
packages only)
closed valves).
Water Temperature is High (water---
Increase water flow, lower water
cooled packages only)
temperature.
Cooler is Plugged (water---cooled
Clean tubes and/or shell --- if tube
packages only)
plugging persists, provide cleaner
water.
Temperature RTD Malfunction
Check connections from RTD.
If adequate, replace RTD.
P1 HI Message
P1 MAX --- 3 psi (.2 Bar) Exceeded
for Pre---Alarm
P1 MAX Exceeded for Shutdown
Discharge Pressure Exceeded
Shutdown Level Because:
Unloading Device (i.e., Blowdown
Check operation of unloading device
Valve, Sullicon Actuator, Optional
.
Spiral Valve) Failed to Operate
Pressure Regulator Maladjusted
Check operation of pressure regulator.
Solenoid Valve Failed
Check operation of solenoid valve
to Operate
Содержание Supervisor II
Страница 1: ...SUPERVISOR Part Number 02250071 398 eSullair Corporation INSTRUCTION MANUAL II ALL MODELS ...
Страница 6: ...Section 1 SAFETY 2 Figure 1 1 Decals ...
Страница 7: ...Section 2 SUPERVISOR II DESCRIPTION 3 Figure 2 1 Supervisor II Panel All Models Except DS 13 ...
Страница 8: ...Section 2 SUPERVISOR II DESCRIPTION 4 Figure 2 1A Supervisor Panel DS 13 ...
Страница 18: ...14 NOTES ...
Страница 22: ...18 NOTES ...
Страница 24: ...20 NOTES ...