Section 5
MAINTENANCE AND TROUBLESHOOTING
25
5.4C TROUBLESHOOTING GUIDE --- LS---16T & LS---20T (Continued)
SYMPTOM
PROBABLE CAUSE
REMEDY
P1 HI Message
Control Air Signal Leaks
Check tube work feeding control
(Continued)
signal for leaks
Control Air Signal Filter Clogged
Service filter assembly
SEP MNTN Message
Plugged separator
Replace separator elements.
dP1 > 10 PSI (0.7 bar)
Check P1 & P2 pressure transducers.
COMPRESSOR DOES NOT
BUILD FULL DISCHARGE
PRESSURE
Air Demand Exceeds Supply
Check air service lines for open
valves or leaks.
Inlet Air Filter Clogged
Check for maintenance message on
Supervisor display. Inspect and/or
change element.
Inlet Valve Not Fully Open
Check actuation and butterfly disc
position.
Pressure Sensor and/or Connections
Check connections from transducer.
at Fault
If adequate, replace transducer.
Blowdown Valve Leaking
Repair or replace.
AIR MNTN Message
Inlet Differential
Replace inlet filter, check inlet switch.
LO COOL Message
(Water---cooled packages only)
Water Pressure Feed Below 10 psig
Check cooling water supply (i.e.,
(0.7 bar)
closed valves).
(Air---Cooled or Water---Cooled
w/canopy)
Fan Motor Overload Tripped
Reset after heater elements cool.
5.4D TROUBLESHOOTING --- DS---13
SYMPTOM/MESSAGE
PROBABLE CAUSE
REMEDY
COMPRESSOR WILL NOT START;
POWER LED OFF
Main Disconnect Switch Open
Close switch.
Line Fuse Blown
Replace fuse.
Control Transformer Fuse Blown
Replace fuse.
MOTOR OL
Motor Starter Overloads Tripped
Reset after heater elements cool down.
Should trouble persist, check whether
motor starter contacts are functioning
properly.
Low Incoming Line Voltage
Check voltage. Should voltage check
low, consult power company.
T---1, T---2 FAIL
Temperature Transducer Failure
Check connections from
transducer. If adequate, replace
transducer.
P---1, P---2 FAIL
Pressure Transducer Failure
Check connections from
transducer. If adequate, replace
transducer.
E---STOP
Emergency Switch Open
Close switch (pull).
(depressed)
Содержание Supervisor II
Страница 1: ...SUPERVISOR Part Number 02250071 398 eSullair Corporation INSTRUCTION MANUAL II ALL MODELS ...
Страница 6: ...Section 1 SAFETY 2 Figure 1 1 Decals ...
Страница 7: ...Section 2 SUPERVISOR II DESCRIPTION 3 Figure 2 1 Supervisor II Panel All Models Except DS 13 ...
Страница 8: ...Section 2 SUPERVISOR II DESCRIPTION 4 Figure 2 1A Supervisor Panel DS 13 ...
Страница 18: ...14 NOTES ...
Страница 22: ...18 NOTES ...
Страница 24: ...20 NOTES ...