SRC Service Manual
Revision 02
Aug 2007
•
Vent the coolant circuit through two venting valves at the
highest points of the coolant circuit:
1. At the top of the coolant tank, and
2. At the top of the coolant piping coming from the air to
coolant heat exchanger.
•
Close the vent valves, and pressurize the coolant circuit to
approximately 15 – 22 psig (1 - 1.5 bar g), using a hand
pump, or other device.