10.2.7 Dewpoint Sensor Error (Warning)
What it means:
Temperature sensor B1 (dewpoint temperature) is short circuited, open, or a
signal outside it’s range (-10
o
C to +90°C).
What it does:
Cuts power to the alarm contacts. Turns on Warning Light & alternates between
“dSE” and the dewpoint reading on the digital display.
To Reset:
Find the cause of the alarm and fix the problem.
Press ALARM RESET to clear alarm. . Power restored to alarm relay, Warning
Light goes off.
Notes:
Alarm can only be cleared if sensor reading is within limits.
10.2.8
Service Required (Warning)
What it means:
Dryer has on for longer than the Service Required Warning Interval (Parameter
B8: Default 6000 hours) without service or inspection.
What it does:
Cuts power to the alarm contacts. Turns on Warning Light & alternates between
“Sr” and the dewpoint reading on the digital display.
To Reset:
Press ALARM RESET. Power restored to alarm relay & Warning Light goes off
for 24 hours.
To reset the alarm for another 6000 hours, contact Sullair or your authorized
Sullair distributor and ensure the dryer & filters are inspected and maintained in
accordance with the schedules in their respective user guides.
The alarm reset (Parameter B3) and it’s interval (Parameter B8) are locked and
can only be modified after entering a special pass code. See Section 9.3 for
further information.
Notes:
Unlike the other alarms, the “Sr” warning is not recorded in the alarm history.