SRC Service Manual
Revision 02
Aug 2007
4. Control System
The SRC-150 to 200 feature a base analog controller, while the SRC-250 to 1000 are fitted with a
microprocessor.
4.1 Power Supply
The following power supplies are offered:
•
115V/1ph/60Hz +/-10% on SRC-125 & 150
•
230V/1ph/60Hz +/-10% on SRC-125 through 250
•
230V/3ph/60Hz +/-10% on SRC-250
•
460V/3ph/60Hz +/-10% on SRC-250 through 1000
•
575V/3ph/60Hz +/-10% on SRC-250 through 1000
4.2 Controls on the SRC-150 to 200
The SRC-150 to 200 use an analog controller. It features the following functions:
•
Dryer on/off switch.
•
Dryer on signal (green lamp).
•
Alarm signal (red lamp).
•
Dew point indicator
o
green
= dew point ok
o
red
= high dew point
o
blue
= risk of freezing
•
Automatic restart (after power failure).
Page 21 of 56