SRC Service Manual
Revision 02
Aug 2007
12.3 Replacing the Control Board (SRC-250 to 1000)
•
Open the electrical box.
•
Remove the white connector containing the electrical supply & digital inputs & outputs.
•
Disconnect the temperature sensor wires.
•
Disconnect the level sensor (SRC-400 to 1000 ONLY) Pull firmly on the connector, being
careful not to damage it.
Electrical supply &
digital input & output
connections
Level sensor
connection
Temperature sensor connections
•
Unscrew the six screws holding the board in place.
•
Replace the old board with the new one.
•
Reinstall the temperature sensors, wires in the same locations.
12.4 Replacing the Drain Valve
•
Loosen the 3 piece union.
•
Unscrew the electrical connector.
•
Remove the fixing nut.
•
Remove the old coil and install the new one.
•
Replace the fixing nut.
•
Reattach the electrical connector.
•
Tighten the 3 piece union.
Page 52 of 56