©2017 Extractor Corporation
115-V 20-Amp 60-Hz SUITMATE
®
Unit
7
TESTING AND OPERATION
After the mounting and all connections are complete, test the SUITMATE
®
unit as follows:
1) Make certain all packaging material is removed from the unit including material around the Motor.
2) Check to see that the Basket is empty and that the Lid moves freely.
3) Press down on the Lid. The unit will start and run for 8 seconds. While the unit is running it should run
smoothly and there should be no excessive vibration or noise.
4) Releasing the lid prior to the completion of the 8 second cycle causes the Basket to stop within one
(1) second.
5) Test the SUITMATE
®
unit by putting a wet swimsuit in the unit according to the instructions on the underside
of the Lid. If there is excessive vibration or noise it is usually caused by the improper loading of the
swimsuit. Be certain that the swimsuit is pushed to the bottom of the Basket and that all material is at least
two inches below the top of the Basket.
INSTALLATION TROUBLESHOOTING
If the SUITMATE
®
unit does not operate, check the following:
1) Check to see if there is power going to the unit. Check the circuit using an A.C. voltmeter set to the
appropriate range
measure across the
³
LINE” side of the GFCI.
2) Ensure that the GFCI switch is in the
³
ON” position. The
³
RESET” button should be depressed and a small
green light should be illuminated.
3) Check to see if there is power from the unit. Check the unit using an A.C. voltmeter to measure across the
³
LOAD” side of the GFCI.
4) Check the TROUBLESHOOTING GUIDE (page 11) in this manual for additional troubleshooting assistance.
FINISHING THE INSTALLATION
Be certain to save this SUITMATE
®
UNIT MANUAL for future reference. If you have any concerns about the
correct installation of the SUITMATE
®
unit, please contact Extractor Corporation at: (Telephone) 800-553-3353,
(Fax) 847-742-3552, or (E-Mail) [email protected].
POSTING THE WALL SIGN
Locate the top edge of the sign 60+/- 1/16” (152.5cm +/- 2mm) above the
À
oor centered over the SUITMATE
®
unit. At this height the sign will not be blocked when the lid is raised. It will also serve as a stop to keep the Lid
from striking the wall behind the unit.
The sign has an adhesive foam backing. Be certain the surface that the sign is to be mounted to is clean and
dry. Without touching the sign to the wall, align the top of the sign 60+/- 1/16” (152.5cm +/- 2mm) above the
À
oor and at the center of the unit. Press the sign to the wall and rub
¿
rmly over the adhesive portion of the sign.