REMOVE AND REPLACE MICRO SWITCH
'
o t
K
i
V
),567
Make certain you have all the correct parts and fasteners necessary for correct installation. Parts used in this
process: (1) AEC1810 Micro Switch, (2) AEC1808 Star Lock Washers, (2) AEC1804 S.S. Nuts, (2) AEC1831
Machine Screws, (1) AEC1250 Gasket, and (1) AEC1245 Micro Switch Box Cover.
REMOVE MICRO SWITCH
1) Turn off the main electrical power to the unit – place a lockout tag on the circuit breaker panel indicating that
the breaker is not to be turned on except by authorized personnel and disconnect the unit before doing any
work on the SUITMATE
®
unit. Simply turning off a switch is NOT enough.
2) Remove SUITMATE
®
unit from the Wall Mount Bracket. See instructions beginning on Page 14. Place the
SUITMATE
®
unit on its front side.
3) Remove the Micro Switch Box Cover to expose the Micro Switch and Riser Cable Assembly by unscrewing
(2) screws. Place the screws aside for reassembly.
4) Unscrew the Turnbuckle Nut on the Riser Cable Turnbuckle to free the Micro Switch’s arm. Set the nut
aside for reassembly.
5) Remove the Nuts and Lock Washers to access the Micro Switch. Set the hardware aside for reassembly.
6) Remove the Micro Switch from the mounting studs.
REPLACE MICRO SWITCH
1) Remove the wires, one at a time, and put each wire in the matching position on the new Micro Switch.
2) Place the newly wired Micro Switch on the mounting studs. Make certain the switch arm extends to the
right. Use the Nuts and Lock Washers previously removed to secure the new Micro Switch.
Note:
Do not over tighten the Nuts!
3) Put the threaded end of the Riser Cable Turnbuckle through the hole in the arm of the Micro Switch. Use
the previously removed Turnbuckle Nut (step 4) to secure the Turnbuckle to the switch arm.
4) Refer to the SUITMATE
®
UNIT MICRO SWITCH ADJUSTMENT PROCEDURE (Page 47) in this manual to
properly adjust the Micro Switch.
5) After the Riser Cable is properly adjusted, replace the Micro Switch Box Cover and secure it in place using
the previously removed or replacement screws.
WARNING!
0DN
e
F
e
U
t
D
in t
K
e
I
o
DP
V
e
DO
on t
K
e
0
i
FU
o
6Z
it
FK
%
o
[
&
o
Y
e
U
i
V
not
GDPDJ
e
G
V
o
t
KD
t
ZD
te
U
FD
nnot ente
U
t
K
e
0
i
FU
o
6Z
it
FK
%
o
[
.
6) Reinstall the SUITMATE
®
unit to the Wall Mount Bracket. See instructions beginning on Page 14.
7) Turn on the main electrical power to the unit and retest to assure proper operation. Refer to TESTING
AND OPERATION on Page 7.
Содержание Swimsuit Water Extractor 115V
Страница 1: ...115V 60Hz Manual Installation Maintenance...
Страница 2: ......
Страница 57: ......
Страница 58: ...v052017...