• If the Basket spins freely, the problem may be due to a loose wire or a broken motor
component. Remove the end cap from the bottom of the motor to visually inspect the motor
components for cracks, frayed wires and broken wires. If anything is found to be broken, contact
Extractor Corporation for additional assistance or replacement parts.
• If the Basket does not spin freely or at all, the problem may be due to an obstruction within
the unit or faulty motor bearings. Check for signs of an obstruction within the unit by gently
pulling the Basket aside and, with a
À
ash light, look down inside the unit for something wrapped
around the Basket or Brake Disc (located around the bottom of the Basket). If foreign objects
are found, try to pull them out with a long hook or other instrument. If the obstruction cannot be
removed in this manner, the Top and Sub-Top may need to be removed to fully access the
inside of the unit. Please refer to Page 15 in this manual for further instruction.
• If no signs of an obstruction can be seen, the issue may be faulty motor bearings.
Please contact Extractor Corporation for additional troubleshooting regarding this issue.
Problem: The unit is humming as soon as power is engaged and before the Lid is depressed.
This could be caused by either a faulty timer or an over-adjustment on the Micro Switch.
• To test for a faulty timer in this instance, place the Lid in the open and upright position and use an A.C.
voltmeter set to the appropriate range to check for power at the #4 (or COM) connection on the Timer.
• If there is power at the #4 (or COM) connection on the Timer with the Lid in the upright
position, the Timer is faulty and should be replaced.
• To check the adjustment on the Micro Switch, please refer to Page 49 in this manual.
Problem: The unit is leaking.
The SUITMATE
®
unit does not have any seals or gaskets that can wear or break down. Leaking is primarily
caused by an obstruction within the interior drain channel, drain hose, or P-trap (if applicable). The interior
drain channel is a two-inch U channel that runs around the perimeter of the interior of the unit. Check for an
obstruction by gently pulling the Basket aside and, with a
À
ash light, look down inside the unit for something
blocking the drain channel or drain opening. If foreign objects are found, try to pull them out with a long hook
or other instrument. If the obstruction cannot be removed in this manner, the Top and Sub-Top may need to be
removed to fully access the inside of the unit. Please refer to Page 15 in this manual for further instruction.
Problem: The GFCI is tripping off every time the unit is run.
•
The
SUITMATE
®
unit should be connected to a 115-V, 20-Amp, 60-Hz dedicated circuit. If the unit
is connected on a circuit with other items or appliances, it is possible that the initial draw of the unit
could be overloading the circuit causing the GFCI to trip off. If the SUITMATE
®
unit is not on a
dedicated circuit, switch it to a 115-V, 20-Amp, 60-Hz dedicated circuit and verify that the problem
is
resolved.
• If the SUITMATE
®
unit is already on a 115V, 20-Amp, 60-Hz dedicated circuit, the GFCI may be faulty,
have a loose connection, or there may be a short within the unit.
• Verify that all wires are securely connected on both the
³
LINE” and
³
LOAD” sides of the GFCI.
If a loose connection is found, correct it, restore power and verify that the problem is resolved.
CAUTION!
0DN
e
F
e
U
t
D
in t
K
e
PD
in e
O
e
F
t
U
i
FDO
S
o
Z
e
U
to t
K
e unit i
V
tu
U
ne
G
o
II
±
D
n
G
O
o
FN
e
G
out
±
E
e
I
o
U
e
E
e
J
innin
J
Z
o
UN
on t
K
e
68,70$7(
®
unit.
Содержание Swimsuit Water Extractor 115V
Страница 1: ...115V 60Hz Manual Installation Maintenance...
Страница 2: ......
Страница 57: ......
Страница 58: ...v052017...