Set the first waveform as below:
Press
〖
No.
〗
soft key and set to 1.
Press
〖
Wave
〗
soft key and set to 1,Sine.
Press
〖
Wave Length
〗
soft key and set to 128.
Press
〖
Repeat
〗
soft key and set to 2.
Set the second waveform as below:
Press
〖
No.
〗
soft key and set to 2.
Press
〖
Wave
〗
and set to 3, Ramp.
Press
〖
Wave Length
〗
soft key and set to 96.
Press
〖
Repeat
〗
soft key and set to 4.
Set the third waveform as below:
Press
〖
No.
〗
soft key and set to 3.
Press
〖
Wave
〗
soft key and set to 89, Third- harmonic.
Press
〖
Wave Length
〗
and set to 4096.
Press
〖
Repeat
〗
soft key and set to 1.
Press
〖
Execute
〗
soft key, the setting waveform sequence is output.
3.17.3Sample rate
Press
〖
Sample Rate
〗
soft key to set sampling rate of the waveform sequence. That is t
o say, the sampling point number in one second of waveform sequence, and the waveform
sequence is output point by point. A period of waveform sequence is expressed as follo
ws.
Sequence period=Sum of N (waveform length
÷
sample rate × times to repeat)
3.17.4 Trigger source
Press
〖
Source
〗
soft key to select the trigger source, if select the internal, the instrument
will use the internal trigger source and the waveform sequence output process is continuou
sly repeated. If select manual, every time press
〖
Manual Trig
〗
soft key, the output of wa
veform sequence will be triggered once. If selected External, the instrument will use exter
nal trigger source, and each effective trigger edge will triggers a waveform sequence outp