UP keyswitch to move to the next element of the parameter.
17.The next element is the Time Minimum for the minimum time the wrench should be in the
cycled or clicked position for each acceptable use of the wrench. This element of the param-
eter is shown as TMIN on the LED Display. Press the SET keyswitch to enter programming
of the element. The display will again be in the "seconds:tenths" mode, with "
0.0
" as the
default value. The whole seconds value will be blinking. To accept this value, simply press
the SET keyswitch. To change the value, use the UP or DOWN keyswitches. When the
desired value is displayed, press the SET keyswitch. This will lock in the displayed value for
the whole seconds and make the tenths of a second digit active. Use the UP or DOWN
keyswitch to obtain the desired value on the display, then use the SET keyswitch to lock in
the value. The display will return to TMIN. Press the UP keyswitch to go to the next element
of the parameter.
18.
BEEP
will appear on the LED keyswitch. Press the SET keyswitch to enter programming of
this element. The LED Display will change to "
ON
". Pressing the UP keyswitch will cause
the display to read "REJECT ONLY", a second press of the UP keyswitch will cause the dis-
play to read "
OFF
". These are the three options for BEEP. Use the UP keyswitch to page
through them until the one desired is displayed, then press the SET keyswitch to lock in the
selection. Press the Up keyswitch to move to the next element of the parameter.
19.The LED Display will change to read "
RELAYS
". Press the SET keyswitch to access the
relay setting options. The current selection (
MOMENTARY
or
LATCHING
) will scroll across
the LED Display. To switch from one to the other, use the UP keyswitch. When the desired
relay setting scrolls, press the SET keyswitch to lock in the selection. Press the UP
keyswitch to advance to the next element of the parameter. See Chapter 7 for pin identifica-
tion and output.
20.The next element is "
CLEAR TOTAL
", and will be displayed scrolling across the LED Display.
To clear the total number of assemblies in the internal counter, press the SET keyswitch.
Press the SET keyswitch again to return to the element selection process. Press the UP
keyswitch to advance to the next element.
21.The next element is "
BATCH
" which will scroll across the LED Display. This is the number of
fasteners in the assembly or subassembly batch. Press the SET keyswitch to access the
batch count setting. The LED Display will show "
/001
" and the leftmost zero will be the active
selection. Up to 299 fasteners may be in a batch. Use the UP keyswitch to page through the
selections (0, 1, 2) then the SET keyswitch to lock in the selection when it is blinking. This
will cause the tens column to become the active selection. Use the UP and DOWN
keyswitches to display the desired number, then the SET keyswitch to lock in the selection.